{"product_id":"fanuc-ai-spindle-amplifier-200vac-input-a06b-6141-h045-copy","title":"Fanuc ai Spindle Amplifier 200VAC-input A06B-6141-H055","description":"\u003ch2 data-section-id=\"dwpgd5\" data-start=\"0\" data-end=\"45\"\u003e🔧 FANUC A06B-6141-H055 – Full Description\u003c\/h2\u003e\n\u003cp data-start=\"47\" data-end=\"296\"\u003eThe \u003cstrong data-start=\"51\" data-end=\"69\"\u003eA06B-6141-H055\u003c\/strong\u003e is a \u003cstrong data-start=\"75\" data-end=\"119\"\u003every high-power spindle amplifier module\u003c\/strong\u003e from \u003cstrong data-start=\"125\" data-end=\"190\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eFANUC\u003c\/span\u003e\u003c\/span\u003e’s Alpha i (αiSP) series\u003c\/strong\u003e, designed to drive \u003cstrong data-start=\"210\" data-end=\"243\"\u003every large CNC spindle motors\u003c\/strong\u003e in \u003cstrong data-start=\"247\" data-end=\"293\"\u003eheavy-duty industrial machining operations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"298\" data-end=\"301\"\u003e\n\u003ch2 data-section-id=\"1sjkmis\" data-start=\"303\" data-end=\"329\"\u003e📌 Basic Identification\u003c\/h2\u003e\n\u003cul data-start=\"331\" data-end=\"552\"\u003e\n\u003cli data-section-id=\"918ynt\" data-start=\"331\" data-end=\"366\"\u003e\n\u003cstrong data-start=\"333\" data-end=\"349\"\u003ePart Number:\u003c\/strong\u003e A06B-6141-H055\u003c\/li\u003e\n\u003cli data-section-id=\"zmw5by\" data-start=\"367\" data-end=\"415\"\u003e\n\u003cstrong data-start=\"369\" data-end=\"378\"\u003eType:\u003c\/strong\u003e Spindle Amplifier \/ Spindle Module\u003c\/li\u003e\n\u003cli data-section-id=\"16p9x4z\" data-start=\"416\" data-end=\"471\"\u003e\n\u003cstrong data-start=\"418\" data-end=\"429\"\u003eSeries:\u003c\/strong\u003e A06B-6141 (αiSP modular spindle drives)\u003c\/li\u003e\n\u003cli data-section-id=\"14auak0\" data-start=\"472\" data-end=\"508\"\u003e\n\u003cstrong data-start=\"474\" data-end=\"484\"\u003eModel:\u003c\/strong\u003e \u003cstrong data-start=\"485\" data-end=\"506\"\u003eAiSP-55 (SPM-55i)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uxila7\" data-start=\"509\" data-end=\"552\"\u003e\n\u003cstrong data-start=\"511\" data-end=\"525\"\u003eInterface:\u003c\/strong\u003e Type-1 spindle interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"554\" data-end=\"557\"\u003e\n\u003ch2 data-section-id=\"gdzl3l\" data-start=\"559\" data-end=\"573\"\u003e⚙️ Function\u003c\/h2\u003e\n\u003cp data-start=\"575\" data-end=\"663\"\u003eThis module serves as the \u003cstrong data-start=\"601\" data-end=\"651\"\u003emain drive and control unit for spindle motors\u003c\/strong\u003e, providing:\u003c\/p\u003e\n\u003cul data-start=\"665\" data-end=\"867\"\u003e\n\u003cli data-section-id=\"1ngoih4\" data-start=\"665\" data-end=\"711\"\u003e🌀 \u003cstrong data-start=\"670\" data-end=\"709\"\u003ePrecise spindle speed (RPM) control\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1454f94\" data-start=\"712\" data-end=\"769\"\u003e⚡ \u003cstrong data-start=\"716\" data-end=\"767\"\u003eHigh torque output for heavy cutting operations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1plzi5y\" data-start=\"770\" data-end=\"815\"\u003e🔄 \u003cstrong data-start=\"775\" data-end=\"813\"\u003eSmooth acceleration \u0026amp; deceleration\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19ycasc\" data-start=\"816\" data-end=\"867\"\u003e🎯 \u003cstrong data-start=\"821\" data-end=\"865\"\u003eClosed-loop feedback control via encoder\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"869\" data-end=\"969\"\u003e\n\u003cp data-start=\"871\" data-end=\"969\"\u003eConverts electrical power into \u003cstrong data-start=\"902\" data-end=\"942\"\u003ehigh-power, precise spindle rotation\u003c\/strong\u003e for demanding machining.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"971\" data-end=\"974\"\u003e\n\u003ch2 data-section-id=\"17jjm1l\" data-start=\"976\" data-end=\"1005\"\u003e⚡ Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1007\" data-end=\"1240\"\u003e\n\u003cli data-section-id=\"bws4w1\" data-start=\"1007\" data-end=\"1034\"\u003e\n\u003cstrong data-start=\"1009\" data-end=\"1025\"\u003ePower Class:\u003c\/strong\u003e ~55 kW\u003c\/li\u003e\n\u003cli data-section-id=\"1sc0s1x\" data-start=\"1035\" data-end=\"1069\"\u003e\n\u003cstrong data-start=\"1037\" data-end=\"1055\"\u003eInput Voltage:\u003c\/strong\u003e 200–240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ief5rg\" data-start=\"1070\" data-end=\"1136\"\u003e\n\u003cstrong data-start=\"1072\" data-end=\"1091\"\u003eOutput Current:\u003c\/strong\u003e Very high current for large spindle motors\u003c\/li\u003e\n\u003cli data-section-id=\"1qxixis\" data-start=\"1137\" data-end=\"1179\"\u003e\n\u003cstrong data-start=\"1139\" data-end=\"1151\"\u003eCooling:\u003c\/strong\u003e Forced air cooling system\u003c\/li\u003e\n\u003cli data-section-id=\"14vlz44\" data-start=\"1180\" data-end=\"1240\"\u003e\n\u003cstrong data-start=\"1182\" data-end=\"1200\"\u003eCommunication:\u003c\/strong\u003e FANUC serial spindle interface (FSSB)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1242\" data-end=\"1245\"\u003e\n\u003ch2 data-section-id=\"1ukuqci\" data-start=\"1247\" data-end=\"1265\"\u003e🧩 Key Features\u003c\/h2\u003e\n\u003cul data-start=\"1267\" data-end=\"1508\"\u003e\n\u003cli data-section-id=\"x8ajgj\" data-start=\"1267\" data-end=\"1336\"\u003e⚙️ \u003cstrong data-start=\"1272\" data-end=\"1298\"\u003eCompact modular design\u003c\/strong\u003e relative to A06B-6111 series drives\u003c\/li\u003e\n\u003cli data-section-id=\"1l5qife\" data-start=\"1337\" data-end=\"1383\"\u003e🔗 Full integration with FANUC CNC systems\u003c\/li\u003e\n\u003cli data-section-id=\"etdol2\" data-start=\"1384\" data-end=\"1443\"\u003e🎯 Stable and precise spindle control under heavy loads\u003c\/li\u003e\n\u003cli data-section-id=\"8xim9c\" data-start=\"1444\" data-end=\"1508\"\u003e🔧 Supports \u003cstrong data-start=\"1458\" data-end=\"1506\"\u003erepair, refurbishment, and exchange programs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1510\" data-end=\"1513\"\u003e\n\u003ch2 data-section-id=\"rwt4mz\" data-start=\"1515\" data-end=\"1533\"\u003e🧩 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1535\" data-end=\"1543\"\u003eUsed in:\u003c\/p\u003e\n\u003cul data-start=\"1545\" data-end=\"1708\"\u003e\n\u003cli data-section-id=\"9nr7ni\" data-start=\"1545\" data-end=\"1570\"\u003eCNC machining centers\u003c\/li\u003e\n\u003cli data-section-id=\"1n8u432\" data-start=\"1571\" data-end=\"1618\"\u003eLarge milling, boring, and turning machines\u003c\/li\u003e\n\u003cli data-section-id=\"eteguy\" data-start=\"1619\" data-end=\"1708\"\u003eIndustrial applications requiring \u003cstrong data-start=\"1655\" data-end=\"1706\"\u003econtinuous high torque and ~55 kW spindle power\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1710\" data-end=\"1713\"\u003e\n\u003ch2 data-section-id=\"lfleh1\" data-start=\"1715\" data-end=\"1742\"\u003e🔧 Internal Construction\u003c\/h2\u003e\n\u003cp data-start=\"1744\" data-end=\"1762\"\u003eInside the module:\u003c\/p\u003e\n\u003cul data-start=\"1764\" data-end=\"1938\"\u003e\n\u003cli data-section-id=\"8xc2om\" data-start=\"1764\" data-end=\"1800\"\u003e\u003cstrong data-start=\"1766\" data-end=\"1798\"\u003ePower PCB (A16B-2203 series)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"5icqay\" data-start=\"1801\" data-end=\"1851\"\u003e\u003cstrong data-start=\"1803\" data-end=\"1849\"\u003eControl PCB (A20B-2100 \/ A20B-2101 series)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1h4abd8\" data-start=\"1852\" data-end=\"1897\"\u003e\n\u003cstrong data-start=\"1854\" data-end=\"1870\"\u003eIGBT modules\u003c\/strong\u003e for high-power switching\u003c\/li\u003e\n\u003cli data-section-id=\"x9sb52\" data-start=\"1898\" data-end=\"1938\"\u003e\u003cstrong data-start=\"1900\" data-end=\"1936\"\u003eCooling system (fan + heat sink)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1940\" data-end=\"2023\"\u003e⚠️ Typically serviced as a \u003cstrong data-start=\"1967\" data-end=\"1986\"\u003ecomplete module\u003c\/strong\u003e, not individual PCBs in the field.\u003c\/p\u003e\n\u003chr data-start=\"2025\" data-end=\"2028\"\u003e\n\u003ch2 data-section-id=\"13h7d5x\" data-start=\"2030\" data-end=\"2057\"\u003e🚨 Common Fault Symptoms\u003c\/h2\u003e\n\u003cp data-start=\"2059\" data-end=\"2106\"\u003eIf the module is faulty, common issues include:\u003c\/p\u003e\n\u003cul data-start=\"2108\" data-end=\"2263\"\u003e\n\u003cli data-section-id=\"18prflc\" data-start=\"2108\" data-end=\"2135\"\u003eSpindle does not rotate\u003c\/li\u003e\n\u003cli data-section-id=\"1wjx3wi\" data-start=\"2136\" data-end=\"2170\"\u003eSP \/ ALM spindle alarms on CNC\u003c\/li\u003e\n\u003cli data-section-id=\"t6dr5i\" data-start=\"2171\" data-end=\"2204\"\u003eOvercurrent or overload trips\u003c\/li\u003e\n\u003cli data-section-id=\"1oqx19c\" data-start=\"2205\" data-end=\"2232\"\u003eSudden stops under load\u003c\/li\u003e\n\u003cli data-section-id=\"1x01w29\" data-start=\"2233\" data-end=\"2263\"\u003eDrive fault LED indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2265\" data-end=\"2268\"\u003e\n\u003ch2 data-section-id=\"17m2vx0\" data-start=\"2270\" data-end=\"2313\"\u003e📊 Position in FANUC Range (6141 Series)\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2315\" data-end=\"2538\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2315\" data-end=\"2332\"\u003e\n\u003ctr data-start=\"2315\" data-end=\"2332\"\u003e\n\u003cth data-start=\"2315\" data-end=\"2323\" data-col-size=\"sm\" class=\"\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"2323\" data-end=\"2332\" data-col-size=\"sm\" class=\"\"\u003ePower\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2349\" data-end=\"2538\"\u003e\n\u003ctr data-start=\"2349\" data-end=\"2367\"\u003e\n\u003ctd data-start=\"2349\" data-end=\"2356\" data-col-size=\"sm\"\u003eH002\u003c\/td\u003e\n\u003ctd data-start=\"2356\" data-end=\"2367\" data-col-size=\"sm\"\u003e~2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2368\" data-end=\"2386\"\u003e\n\u003ctd data-start=\"2368\" data-end=\"2375\" data-col-size=\"sm\"\u003eH006\u003c\/td\u003e\n\u003ctd data-start=\"2375\" data-end=\"2386\" data-col-size=\"sm\"\u003e~5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2387\" data-end=\"2404\"\u003e\n\u003ctd data-start=\"2387\" data-end=\"2394\" data-col-size=\"sm\"\u003eH011\u003c\/td\u003e\n\u003ctd data-start=\"2394\" data-end=\"2404\" data-col-size=\"sm\"\u003e~11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2405\" data-end=\"2422\"\u003e\n\u003ctd data-start=\"2405\" data-end=\"2412\" data-col-size=\"sm\"\u003eH015\u003c\/td\u003e\n\u003ctd data-start=\"2412\" data-end=\"2422\" data-col-size=\"sm\"\u003e~15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2423\" data-end=\"2440\"\u003e\n\u003ctd data-start=\"2423\" data-end=\"2430\" data-col-size=\"sm\"\u003eH022\u003c\/td\u003e\n\u003ctd data-start=\"2430\" data-end=\"2440\" data-col-size=\"sm\"\u003e~22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2441\" data-end=\"2458\"\u003e\n\u003ctd data-start=\"2441\" data-end=\"2448\" data-col-size=\"sm\"\u003eH026\u003c\/td\u003e\n\u003ctd data-start=\"2448\" data-end=\"2458\" data-col-size=\"sm\"\u003e~26 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2459\" data-end=\"2476\"\u003e\n\u003ctd data-start=\"2459\" data-end=\"2466\" data-col-size=\"sm\"\u003eH030\u003c\/td\u003e\n\u003ctd data-start=\"2466\" data-end=\"2476\" data-col-size=\"sm\"\u003e~30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2477\" data-end=\"2494\"\u003e\n\u003ctd data-start=\"2477\" data-end=\"2484\" data-col-size=\"sm\"\u003eH037\u003c\/td\u003e\n\u003ctd data-start=\"2484\" data-end=\"2494\" data-col-size=\"sm\"\u003e~37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2495\" data-end=\"2512\"\u003e\n\u003ctd data-start=\"2495\" data-end=\"2502\" data-col-size=\"sm\"\u003eH045\u003c\/td\u003e\n\u003ctd data-start=\"2502\" data-end=\"2512\" data-col-size=\"sm\"\u003e~45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2513\" data-end=\"2538\"\u003e\n\u003ctd data-start=\"2513\" data-end=\"2524\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2515\" data-end=\"2523\"\u003eH055\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2524\" data-end=\"2538\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2526\" data-end=\"2536\"\u003e~55 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cblockquote data-start=\"2540\" data-end=\"2631\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2631\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2629\"\u003eH055 = top-tier power module in the 6141 series for extremely heavy machining loads\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2633\" data-end=\"2636\"\u003e\n\u003ch2 data-section-id=\"xttt94\" data-start=\"2638\" data-end=\"2652\"\u003e🔄 Variants\u003c\/h2\u003e\n\u003cp data-start=\"2654\" data-end=\"2668\"\u003eCommon suffix:\u003c\/p\u003e\n\u003cul data-start=\"2670\" data-end=\"2736\"\u003e\n\u003cli data-section-id=\"1dbi92y\" data-start=\"2670\" data-end=\"2736\"\u003e\n\u003cstrong data-start=\"2672\" data-end=\"2695\"\u003eA06B-6141-H055#H580\u003c\/strong\u003e – minor firmware\/interface differences\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-section-id=\"1f0f770\" data-start=\"2743\" data-end=\"2755\"\u003e✅ Summary\u003c\/h2\u003e\n\u003cp data-start=\"2757\" data-end=\"2958\"\u003e\u003cstrong data-start=\"2757\" data-end=\"2775\"\u003eA06B-6141-H055\u003c\/strong\u003e\u003cbr data-start=\"2775\" data-end=\"2778\"\u003e➡️ FANUC \u003cstrong data-start=\"2787\" data-end=\"2831\"\u003eAlpha i AiSP-55 spindle amplifier module\u003c\/strong\u003e\u003cbr data-start=\"2831\" data-end=\"2834\"\u003e➡️ Designed for \u003cstrong data-start=\"2850\" data-end=\"2875\"\u003e~55 kW spindle motors\u003c\/strong\u003e\u003cbr data-start=\"2875\" data-end=\"2878\"\u003e➡️ Compact, very high-power module for \u003cstrong data-start=\"2917\" data-end=\"2956\"\u003eheavy-duty CNC spindle applications\u003c\/strong\u003e\u003c\/p\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45002561126536,"sku":"A06B-6141-H055","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-04-07T144229.287.jpg?v=1775553157","url":"https:\/\/jjautomation.in\/products\/fanuc-ai-spindle-amplifier-200vac-input-a06b-6141-h045-copy","provider":"JJAutomation","version":"1.0","type":"link"}