{"product_id":"fanuc-profibus-master-board-for-0i-b-0i-mate-b-a20b-8100-0470-copy","title":"Fanuc PROFIBUS Slave board for 0i-B\/ 0i Mate-B\/ 0i-C\/ 0i Mate-C\/ 16i\/ 18i\/ 21i A20B-8100-0440","description":"\u003ch3 data-start=\"81\" data-end=\"148\"\u003e📌 \u003cstrong data-start=\"88\" data-end=\"148\"\u003eFANUC A20B-8100-0440 — PROFIBUS-DP Slave Interface Board\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"150\" data-end=\"502\"\u003e\u003cstrong data-start=\"150\" data-end=\"165\"\u003eWhat it is:\u003c\/strong\u003e\u003cbr data-start=\"165\" data-end=\"168\"\u003eThe \u003cstrong data-start=\"172\" data-end=\"196\"\u003eFANUC A20B-8100-0440\u003c\/strong\u003e is a \u003cstrong data-start=\"202\" data-end=\"261\"\u003ePROFIBUS-DP Slave interface printed circuit board (PCB)\u003c\/strong\u003e used in FANUC CNC control systems to provide \u003cstrong data-start=\"307\" data-end=\"356\"\u003ePROFIBUS distributed automation communication\u003c\/strong\u003e. It allows a FANUC controller or expansion subsystem to act as a \u003cstrong data-start=\"422\" data-end=\"438\"\u003eslave device\u003c\/strong\u003e on a PROFIBUS-DP network. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"504\" data-end=\"535\"\u003e\u003cstrong data-start=\"504\" data-end=\"533\"\u003eKey Functions \u0026amp; Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"536\" data-end=\"1619\"\u003e\n\u003cli data-start=\"536\" data-end=\"911\"\u003e\n\u003cp data-start=\"538\" data-end=\"911\"\u003e🔗 \u003cstrong data-start=\"541\" data-end=\"578\"\u003ePROFIBUS-DP Slave Communications:\u003c\/strong\u003e This board implements the \u003cstrong data-start=\"605\" data-end=\"629\"\u003ePROFIBUS-DP protocol\u003c\/strong\u003e in \u003cstrong data-start=\"633\" data-end=\"647\"\u003eslave mode\u003c\/strong\u003e, enabling the control system to exchange data with a PROFIBUS master (such as a PLC or higher-level controller). PROFIBUS-DP is a widely used industrial fieldbus standard for fast, deterministic communication in automation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"912\" data-end=\"1156\"\u003e\n\u003cp data-start=\"914\" data-end=\"1156\"\u003e🤝 \u003cstrong data-start=\"917\" data-end=\"941\"\u003eNetwork Integration:\u003c\/strong\u003e Typically used where FANUC controllers are integrated into a larger factory automation system that uses PROFIBUS for distributed I\/O, remote device control, or data exchange. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1157\" data-end=\"1429\"\u003e\n\u003cp data-start=\"1159\" data-end=\"1429\"\u003e🛠️ \u003cstrong data-start=\"1163\" data-end=\"1190\"\u003eModular Expansion Card:\u003c\/strong\u003e Installed as an \u003cstrong data-start=\"1207\" data-end=\"1232\"\u003eadd-on interface card\u003c\/strong\u003e within the controller’s electronics assembly or expansion slots — it does not replace the main CPU but provides additional network communication capability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1619\"\u003e\n\u003cp data-start=\"1432\" data-end=\"1619\"\u003e🧪 \u003cstrong data-start=\"1435\" data-end=\"1462\"\u003eLegacy \u0026amp; Compatibility:\u003c\/strong\u003e Often found on controllers like Series \u003cstrong data-start=\"1502\" data-end=\"1532\"\u003e16i, 18i, and 21i i-Series\u003c\/strong\u003e where modular communication cards are supported. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1621\" data-end=\"1645\"\u003e\u003cstrong data-start=\"1621\" data-end=\"1643\"\u003eTypical Use Cases:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1646\" data-end=\"1890\"\u003e\n\u003cli data-start=\"1646\" data-end=\"1771\"\u003e\n\u003cp data-start=\"1648\" data-end=\"1771\"\u003e\u003cstrong data-start=\"1648\" data-end=\"1681\"\u003eDistributed Factory Networks:\u003c\/strong\u003e Connects FANUC CNC units as PROFIBUS slaves to a central supervisory controller or PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1772\" data-end=\"1890\"\u003e\n\u003cp data-start=\"1774\" data-end=\"1890\"\u003e\u003cstrong data-start=\"1774\" data-end=\"1799\"\u003eMachine Data Sharing:\u003c\/strong\u003e Allows real-time status, command, and I\/O data to be shared over an industrial bus system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1892\" data-end=\"1904\"\u003e\u003cstrong data-start=\"1892\" data-end=\"1902\"\u003eNotes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1905\" data-end=\"2181\"\u003e\n\u003cli data-start=\"1905\" data-end=\"2081\"\u003e\n\u003cp data-start=\"1907\" data-end=\"2081\"\u003eThis part is \u003cstrong data-start=\"1920\" data-end=\"1945\"\u003ediscontinued by FANUC\u003c\/strong\u003e and typically available through industrial suppliers as \u003cstrong data-start=\"2002\" data-end=\"2034\"\u003enew, surplus, or refurbished\u003c\/strong\u003e units. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2082\" data-end=\"2181\"\u003e\n\u003cp data-start=\"2084\" data-end=\"2181\"\u003eCore exchange and repair options depend on vendor policies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":44705540735112,"sku":"A20B-8100-0440","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-01-21T170513.789.jpg?v=1768995323","url":"https:\/\/jjautomation.in\/products\/fanuc-profibus-master-board-for-0i-b-0i-mate-b-a20b-8100-0470-copy","provider":"JJAutomation","version":"1.0","type":"link"}