{"product_id":"mitsubishi-m80-ac-reactor-d-al-37k-copy","title":"Mitsubishi M80 AC Reactor D-AL-45K","description":"\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"80a06bbe-4fa9-4de8-b852-ee108ebe9d52\" class=\"\"\u003e\n\u003csection data-turn=\"user\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-93\" data-turn-id-container=\"80a06bbe-4fa9-4de8-b852-ee108ebe9d52\" data-turn-id=\"80a06bbe-4fa9-4de8-b852-ee108ebe9d52\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\"\u003e\u003c\/section\u003e\n\u003cp data-start=\"0\" data-end=\"179\"\u003eThe \u003cstrong data-start=\"4\" data-end=\"27\"\u003eMitsubishi D-AL-45K\u003c\/strong\u003e is an \u003cstrong data-start=\"34\" data-end=\"69\"\u003eAC line reactor (input reactor)\u003c\/strong\u003e used in \u003cstrong data-start=\"78\" data-end=\"113\"\u003eMDS-E \/ MDS-D CNC drive systems\u003c\/strong\u003e, installed between the \u003cstrong data-start=\"137\" data-end=\"178\"\u003eAC supply and the converter (CV) unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"181\" data-end=\"254\"\u003eIt is a \u003cstrong data-start=\"189\" data-end=\"231\"\u003epower quality and protection component\u003c\/strong\u003e, not a drive or motor.\u003c\/p\u003e\n\u003chr data-start=\"256\" data-end=\"259\"\u003e\n\u003ch2 data-section-id=\"m2ve78\" data-start=\"261\" data-end=\"296\"\u003e🔧 Key Specifications (D-AL-45K)\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"298\" data-end=\"681\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"298\" data-end=\"323\"\u003e\n\u003ctr data-start=\"298\" data-end=\"323\"\u003e\n\u003cth data-start=\"298\" data-end=\"314\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"314\" data-end=\"323\" data-col-size=\"md\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"334\" data-end=\"681\"\u003e\n\u003ctr data-start=\"334\" data-end=\"370\"\u003e\n\u003ctd data-start=\"334\" data-end=\"341\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"341\" data-end=\"370\" data-col-size=\"md\"\u003eAC Reactor (Line Reactor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"371\" data-end=\"410\"\u003e\n\u003ctd data-start=\"371\" data-end=\"380\" data-col-size=\"sm\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-start=\"380\" data-end=\"410\" data-col-size=\"md\"\u003eMitsubishi CNC MDS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"411\" data-end=\"437\"\u003e\n\u003ctd data-start=\"411\" data-end=\"428\" data-col-size=\"sm\"\u003eRated Capacity\u003c\/td\u003e\n\u003ctd data-start=\"428\" data-end=\"437\" data-col-size=\"md\"\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"438\" data-end=\"464\"\u003e\n\u003ctd data-start=\"438\" data-end=\"454\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-start=\"454\" data-end=\"464\" data-col-size=\"md\"\u003e~162 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"465\" data-end=\"497\"\u003e\n\u003ctd data-start=\"465\" data-end=\"481\" data-col-size=\"sm\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd data-start=\"481\" data-end=\"497\" data-col-size=\"md\"\u003e200–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"498\" data-end=\"522\"\u003e\n\u003ctd data-start=\"498\" data-end=\"510\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"510\" data-end=\"522\" data-col-size=\"md\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"523\" data-end=\"584\"\u003e\n\u003ctd data-start=\"523\" data-end=\"534\" data-col-size=\"sm\"\u003eFunction\u003c\/td\u003e\n\u003ctd data-start=\"534\" data-end=\"584\" data-col-size=\"md\"\u003eHarmonic suppression + inrush current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"585\" data-end=\"625\"\u003e\n\u003ctd data-start=\"585\" data-end=\"602\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-start=\"602\" data-end=\"625\" data-col-size=\"md\"\u003eNatural air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"626\" data-end=\"681\"\u003e\n\u003ctd data-start=\"626\" data-end=\"641\" data-col-size=\"sm\"\u003eInstallation\u003c\/td\u003e\n\u003ctd data-start=\"641\" data-end=\"681\" data-col-size=\"md\"\u003eSeries connection with CV unit input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"683\" data-end=\"909\"\u003e📌 Mitsubishi CNC specification tables confirm:\u003cbr data-start=\"730\" data-end=\"733\"\u003e\u003cstrong data-start=\"733\" data-end=\"797\"\u003eD-AL-45K is matched with MDS-E-CV-450 (45 kW converter unit)\u003c\/strong\u003e and is part of the standard input reactor lineup for CNC drive systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"911\" data-end=\"914\"\u003e\n\u003ch2 data-section-id=\"mzz3kp\" data-start=\"916\" data-end=\"934\"\u003e⚙️ What it does\u003c\/h2\u003e\n\u003cp data-start=\"935\" data-end=\"980\"\u003eThe D-AL-45K is installed in CNC cabinets to:\u003c\/p\u003e\n\u003cul data-start=\"982\" data-end=\"1240\"\u003e\n\u003cli data-section-id=\"17gd524\" data-start=\"982\" data-end=\"1040\"\u003eReduce harmonic distortion sent back to the power grid\u003c\/li\u003e\n\u003cli data-section-id=\"13xd4k7\" data-start=\"1041\" data-end=\"1097\"\u003eLimit inrush current when powering ON the CNC system\u003c\/li\u003e\n\u003cli data-section-id=\"6pjk0w\" data-start=\"1098\" data-end=\"1156\"\u003eProtect the CV (converter) unit from electrical stress\u003c\/li\u003e\n\u003cli data-section-id=\"nlq54b\" data-start=\"1157\" data-end=\"1202\"\u003eImprove power factor and system stability\u003c\/li\u003e\n\u003cli data-section-id=\"jeisy4\" data-start=\"1203\" data-end=\"1240\"\u003eSmooth incoming 3-phase AC supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1242\" data-end=\"1245\"\u003e\n\u003ch2 data-section-id=\"eujykb\" data-start=\"1247\" data-end=\"1274\"\u003e🔌 Typical matching unit\u003c\/h2\u003e\n\u003cul data-start=\"1275\" data-end=\"1320\"\u003e\n\u003cli data-section-id=\"12r0q\" data-start=\"1275\" data-end=\"1320\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1320\"\u003eMDS-E-CV-450 (45 kW CNC converter unit)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1322\" data-end=\"1325\"\u003e\n\u003ch2 data-section-id=\"2sl8er\" data-start=\"1327\" data-end=\"1341\"\u003e🏭 Features\u003c\/h2\u003e\n\u003cul data-start=\"1342\" data-end=\"1530\"\u003e\n\u003cli data-section-id=\"1bi5wqx\" data-start=\"1342\" data-end=\"1391\"\u003ePassive coil (no electronics → very reliable)\u003c\/li\u003e\n\u003cli data-section-id=\"khftnc\" data-start=\"1392\" data-end=\"1429\"\u003eImproves CNC system power quality\u003c\/li\u003e\n\u003cli data-section-id=\"131wcvf\" data-start=\"1430\" data-end=\"1464\"\u003eReduces electrical noise (EMI)\u003c\/li\u003e\n\u003cli data-section-id=\"1gyfjys\" data-start=\"1465\" data-end=\"1499\"\u003eExtends life of converter unit\u003c\/li\u003e\n\u003cli data-section-id=\"1ysv9yx\" data-start=\"1500\" data-end=\"1530\"\u003eMaintenance-free operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1532\" data-end=\"1535\"\u003e\n\u003ch2 data-section-id=\"v94eho\" data-start=\"1537\" data-end=\"1555\"\u003e📍 Applications\u003c\/h2\u003e\n\u003cul data-start=\"1556\" data-end=\"1691\"\u003e\n\u003cli data-section-id=\"9nr7ni\" data-start=\"1556\" data-end=\"1581\"\u003eCNC machining centers\u003c\/li\u003e\n\u003cli data-section-id=\"1ijs4lp\" data-start=\"1582\" data-end=\"1606\"\u003eCNC turning machines\u003c\/li\u003e\n\u003cli data-section-id=\"1s29gus\" data-start=\"1607\" data-end=\"1639\"\u003eHeavy industrial CNC systems\u003c\/li\u003e\n\u003cli data-section-id=\"10a5l2s\" data-start=\"1640\" data-end=\"1691\"\u003eMitsubishi MELDAS drive cabinets (MDS-E series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45884527902856,"sku":"D-AL-45K","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-05-26T131926.893.jpg?v=1779781774","url":"https:\/\/jjautomation.in\/products\/mitsubishi-m80-ac-reactor-d-al-37k-copy","provider":"JJAutomation","version":"1.0","type":"link"}