{"product_id":"mitsubishi-m80-ac-reactor-d-al-45k-copy","title":"Mitsubishi M80 AC Reactor D-AL-55K","description":"\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"80a06bbe-4fa9-4de8-b852-ee108ebe9d52\" class=\"\"\u003e\n\u003csection data-turn=\"user\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-93\" data-turn-id-container=\"80a06bbe-4fa9-4de8-b852-ee108ebe9d52\" data-turn-id=\"80a06bbe-4fa9-4de8-b852-ee108ebe9d52\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\"\u003e\u003c\/section\u003e\n\u003cp data-start=\"0\" data-end=\"177\"\u003eThe \u003cstrong data-start=\"4\" data-end=\"27\"\u003eMitsubishi D-AL-55K\u003c\/strong\u003e is an \u003cstrong data-start=\"34\" data-end=\"69\"\u003eAC line reactor (input reactor)\u003c\/strong\u003e used in \u003cstrong data-start=\"78\" data-end=\"113\"\u003eMDS-E \/ MDS-D CNC drive systems\u003c\/strong\u003e, installed on the \u003cstrong data-start=\"132\" data-end=\"176\"\u003eAC input side of the converter (CV) unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"179\" data-end=\"252\"\u003eIt is a \u003cstrong data-start=\"187\" data-end=\"229\"\u003epower-quality and protection component\u003c\/strong\u003e, not a motor or drive.\u003c\/p\u003e\n\u003chr data-start=\"254\" data-end=\"257\"\u003e\n\u003ch2 data-section-id=\"m2t30l\" data-start=\"259\" data-end=\"294\"\u003e🔧 Key Specifications (D-AL-55K)\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"296\" data-end=\"668\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"296\" data-end=\"321\"\u003e\n\u003ctr data-start=\"296\" data-end=\"321\"\u003e\n\u003cth data-start=\"296\" data-end=\"312\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"312\" data-end=\"321\" data-col-size=\"md\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"332\" data-end=\"668\"\u003e\n\u003ctr data-start=\"332\" data-end=\"358\"\u003e\n\u003ctd data-start=\"332\" data-end=\"339\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"339\" data-end=\"358\" data-col-size=\"md\"\u003eAC Line Reactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"359\" data-end=\"398\"\u003e\n\u003ctd data-start=\"359\" data-end=\"368\" data-col-size=\"sm\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-start=\"368\" data-end=\"398\" data-col-size=\"md\"\u003eMitsubishi CNC MDS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"399\" data-end=\"425\"\u003e\n\u003ctd data-start=\"399\" data-end=\"416\" data-col-size=\"sm\"\u003eRated Capacity\u003c\/td\u003e\n\u003ctd data-start=\"416\" data-end=\"425\" data-col-size=\"md\"\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"426\" data-end=\"451\"\u003e\n\u003ctd data-start=\"426\" data-end=\"442\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"442\" data-end=\"451\"\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"452\" data-end=\"484\"\u003e\n\u003ctd data-start=\"452\" data-end=\"468\" data-col-size=\"sm\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"468\" data-end=\"484\"\u003e200–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"485\" data-end=\"509\"\u003e\n\u003ctd data-start=\"485\" data-end=\"497\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"497\" data-end=\"509\" data-col-size=\"md\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"510\" data-end=\"571\"\u003e\n\u003ctd data-start=\"510\" data-end=\"521\" data-col-size=\"sm\"\u003eFunction\u003c\/td\u003e\n\u003ctd data-start=\"521\" data-end=\"571\" data-col-size=\"md\"\u003eHarmonic suppression + inrush current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"572\" data-end=\"612\"\u003e\n\u003ctd data-start=\"572\" data-end=\"589\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"589\" data-end=\"612\"\u003eNatural air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"613\" data-end=\"668\"\u003e\n\u003ctd data-start=\"613\" data-end=\"628\" data-col-size=\"sm\"\u003eInstallation\u003c\/td\u003e\n\u003ctd data-start=\"628\" data-end=\"668\" data-col-size=\"md\"\u003eSeries connection with CV unit input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"670\" data-end=\"881\"\u003e📌 Confirmed from Mitsubishi CNC specification tables, \u003cstrong data-start=\"725\" data-end=\"789\"\u003eD-AL-55K is matched with MDS-E-CV-550 (55 kW converter unit)\u003c\/strong\u003e and is the largest standard reactor in this lineup. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"883\" data-end=\"886\"\u003e\n\u003ch2 data-section-id=\"mzz3kp\" data-start=\"888\" data-end=\"906\"\u003e⚙️ What it does\u003c\/h2\u003e\n\u003cp data-start=\"907\" data-end=\"952\"\u003eThe D-AL-55K is installed in CNC cabinets to:\u003c\/p\u003e\n\u003cul data-start=\"954\" data-end=\"1220\"\u003e\n\u003cli data-section-id=\"17gd524\" data-start=\"954\" data-end=\"1012\"\u003eReduce harmonic distortion sent back to the power grid\u003c\/li\u003e\n\u003cli data-section-id=\"13xd4k7\" data-start=\"1013\" data-end=\"1069\"\u003eLimit inrush current when powering ON the CNC system\u003c\/li\u003e\n\u003cli data-section-id=\"6pjk0w\" data-start=\"1070\" data-end=\"1128\"\u003eProtect the CV (converter) unit from electrical stress\u003c\/li\u003e\n\u003cli data-section-id=\"3mc1fo\" data-start=\"1129\" data-end=\"1182\"\u003eImprove power factor and overall system stability\u003c\/li\u003e\n\u003cli data-section-id=\"jeisy4\" data-start=\"1183\" data-end=\"1220\"\u003eSmooth incoming 3-phase AC supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1222\" data-end=\"1225\"\u003e\n\u003ch2 data-section-id=\"eujykb\" data-start=\"1227\" data-end=\"1254\"\u003e🔌 Typical matching unit\u003c\/h2\u003e\n\u003cul data-start=\"1255\" data-end=\"1300\"\u003e\n\u003cli data-section-id=\"1p2s02y\" data-start=\"1255\" data-end=\"1300\"\u003e\u003cstrong data-start=\"1257\" data-end=\"1300\"\u003eMDS-E-CV-550 (55 kW CNC converter unit)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1302\" data-end=\"1305\"\u003e\n\u003ch2 data-section-id=\"2sl8er\" data-start=\"1307\" data-end=\"1321\"\u003e🏭 Features\u003c\/h2\u003e\n\u003cul data-start=\"1322\" data-end=\"1525\"\u003e\n\u003cli data-section-id=\"ief8bn\" data-start=\"1322\" data-end=\"1385\"\u003ePassive coil design (very high reliability, no electronics)\u003c\/li\u003e\n\u003cli data-section-id=\"khftnc\" data-start=\"1386\" data-end=\"1423\"\u003eImproves CNC system power quality\u003c\/li\u003e\n\u003cli data-section-id=\"131wcvf\" data-start=\"1424\" data-end=\"1458\"\u003eReduces electrical noise (EMI)\u003c\/li\u003e\n\u003cli data-section-id=\"mlaz9t\" data-start=\"1459\" data-end=\"1494\"\u003eExtends converter unit lifespan\u003c\/li\u003e\n\u003cli data-section-id=\"1ysv9yx\" data-start=\"1495\" data-end=\"1525\"\u003eMaintenance-free operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1527\" data-end=\"1530\"\u003e\n\u003ch2 data-section-id=\"v94eho\" data-start=\"1532\" data-end=\"1550\"\u003e📍 Applications\u003c\/h2\u003e\n\u003cul data-start=\"1551\" data-end=\"1686\"\u003e\n\u003cli data-section-id=\"9nr7ni\" data-start=\"1551\" data-end=\"1576\"\u003eCNC machining centers\u003c\/li\u003e\n\u003cli data-section-id=\"1ijs4lp\" data-start=\"1577\" data-end=\"1601\"\u003eCNC turning machines\u003c\/li\u003e\n\u003cli data-section-id=\"1s29gus\" data-start=\"1602\" data-end=\"1634\"\u003eHeavy industrial CNC systems\u003c\/li\u003e\n\u003cli data-section-id=\"10a5l2s\" data-start=\"1635\" data-end=\"1686\"\u003eMitsubishi MELDAS drive cabinets (MDS-E series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45884531507336,"sku":"D-AL-55K","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-05-26T131926.893.jpg?v=1779781774","url":"https:\/\/jjautomation.in\/products\/mitsubishi-m80-ac-reactor-d-al-45k-copy","provider":"JJAutomation","version":"1.0","type":"link"}