{"product_id":"mitsubishi-m80-ac-reactor-dh-al-18-5k-copy","title":"Mitsubishi M80 AC Reactor DH-AL-30К","description":"\u003cp data-start=\"0\" data-end=\"116\"\u003eDH-AL-30K is a \u003cstrong data-start=\"15\" data-end=\"64\"\u003eMitsubishi Electric AC reactor (line reactor)\u003c\/strong\u003e used in CNC servo and spindle power supply systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3h1ku8\" data-start=\"118\" data-end=\"133\"\u003eDescription\u003c\/h3\u003e\n\u003cul data-start=\"134\" data-end=\"412\"\u003e\n\u003cli data-section-id=\"zwfwez\" data-start=\"134\" data-end=\"234\"\u003e\n\u003cstrong data-start=\"136\" data-end=\"153\"\u003eManufacturer:\u003c\/strong\u003e \u003ca data-start=\"154\" data-end=\"234\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.mitsubishielectric.com?utm_source=chatgpt.com\"\u003eMitsubishi Electric\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gpp09j\" data-start=\"235\" data-end=\"290\"\u003e\n\u003cstrong data-start=\"237\" data-end=\"248\"\u003eSeries:\u003c\/strong\u003e DH-AL series (MDS-EH \/ MDS-DH compatible)\u003c\/li\u003e\n\u003cli data-section-id=\"ranhw4\" data-start=\"291\" data-end=\"313\"\u003e\n\u003cstrong data-start=\"293\" data-end=\"303\"\u003eModel:\u003c\/strong\u003e DH-AL-30K\u003c\/li\u003e\n\u003cli data-section-id=\"q0gz60\" data-start=\"314\" data-end=\"378\"\u003e\n\u003cstrong data-start=\"316\" data-end=\"325\"\u003eType:\u003c\/strong\u003e AC Line Reactor (input reactor for CNC power supply)\u003c\/li\u003e\n\u003cli data-section-id=\"1v6hn75\" data-start=\"379\" data-end=\"412\"\u003e\n\u003cstrong data-start=\"381\" data-end=\"400\"\u003eRated Capacity:\u003c\/strong\u003e 30 kW class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1xnyxh\" data-start=\"414\" data-end=\"436\"\u003ePurpose \/ Function\u003c\/h3\u003e\n\u003cp data-start=\"437\" data-end=\"569\"\u003eThis component is \u003cstrong data-start=\"455\" data-end=\"482\"\u003enot a drive or inverter\u003c\/strong\u003e. It is a passive inductive device installed on the AC input side of CNC power systems.\u003c\/p\u003e\n\u003cp data-start=\"571\" data-end=\"585\"\u003eIt is used to:\u003c\/p\u003e\n\u003cul data-start=\"586\" data-end=\"840\"\u003e\n\u003cli data-section-id=\"18oy1hv\" data-start=\"586\" data-end=\"641\"\u003eReduce harmonic distortion from CNC converter units\u003c\/li\u003e\n\u003cli data-section-id=\"1nsfs94\" data-start=\"642\" data-end=\"684\"\u003eLimit inrush current when switching ON\u003c\/li\u003e\n\u003cli data-section-id=\"11q9fkk\" data-start=\"685\" data-end=\"735\"\u003eProtect the MDS power supply rectifier section\u003c\/li\u003e\n\u003cli data-section-id=\"1flu4qg\" data-start=\"736\" data-end=\"796\"\u003eImprove power factor and stabilize the electrical supply\u003c\/li\u003e\n\u003cli data-section-id=\"nymueo\" data-start=\"797\" data-end=\"840\"\u003eReduce stress and heating in the system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"su5kly\" data-start=\"842\" data-end=\"864\"\u003eCompatible Systems\u003c\/h3\u003e\n\u003cp data-start=\"865\" data-end=\"927\"\u003eFrom Mitsubishi CNC specifications, DH-AL-30K is matched with:\u003c\/p\u003e\n\u003cul data-start=\"928\" data-end=\"1007\"\u003e\n\u003cli data-section-id=\"1289cd0\" data-start=\"928\" data-end=\"947\"\u003e\u003cstrong data-start=\"930\" data-end=\"947\"\u003eMDS-EH-CV-300\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1wxruiw\" data-start=\"948\" data-end=\"1007\"\u003e\n\u003cstrong data-start=\"950\" data-end=\"967\"\u003eMDS-DH-CV-300\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1xevv0n\" data-start=\"1009\" data-end=\"1041\"\u003eElectrical Ratings (typical)\u003c\/h3\u003e\n\u003cul data-start=\"1042\" data-end=\"1207\"\u003e\n\u003cli data-section-id=\"19gdgnm\" data-start=\"1042\" data-end=\"1071\"\u003e\n\u003cstrong data-start=\"1044\" data-end=\"1062\"\u003eRated current:\u003c\/strong\u003e ~110 A\u003c\/li\u003e\n\u003cli data-section-id=\"1p1z5se\" data-start=\"1072\" data-end=\"1116\"\u003e\n\u003cstrong data-start=\"1074\" data-end=\"1092\"\u003eVoltage class:\u003c\/strong\u003e 380–480 VAC (3-phase)\u003c\/li\u003e\n\u003cli data-section-id=\"18xe814\" data-start=\"1117\" data-end=\"1144\"\u003e\n\u003cstrong data-start=\"1119\" data-end=\"1133\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"gn5xsa\" data-start=\"1145\" data-end=\"1207\"\u003e\n\u003cstrong data-start=\"1147\" data-end=\"1163\"\u003eApplication:\u003c\/strong\u003e Input side reactor for CNC converter unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"te4j96\" data-start=\"1209\" data-end=\"1228\"\u003eSystem Position\u003c\/h3\u003e\n\u003cp data-start=\"1229\" data-end=\"1323\"\u003eAC mains → \u003cstrong data-start=\"1240\" data-end=\"1261\"\u003eDH-AL-30K reactor\u003c\/strong\u003e → MDS-EH \/ DH CV power supply → DC bus → servo\/spindle drives\u003c\/p\u003e\n\u003ch3 data-section-id=\"q1d0al\" data-start=\"1325\" data-end=\"1338\"\u003eKey Point\u003c\/h3\u003e\n\u003cul data-start=\"1339\" data-end=\"1492\"\u003e\n\u003cli data-section-id=\"jccu77\" data-start=\"1339\" data-end=\"1381\"\u003eIt is a \u003cstrong data-start=\"1349\" data-end=\"1381\"\u003epure passive coil (inductor)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nxhvtb\" data-start=\"1382\" data-end=\"1424\"\u003eIt does \u003cstrong data-start=\"1392\" data-end=\"1424\"\u003enot convert or control power\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lhlsn6\" data-start=\"1425\" data-end=\"1492\"\u003eIts job is \u003cstrong data-start=\"1438\" data-end=\"1492\"\u003eprotection + filtering + power quality improvement\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1494\" data-end=\"1693\"\u003eIf you want, I can also give you a \u003cstrong data-start=\"1529\" data-end=\"1587\"\u003efull pairing chart (7.5K to 75K DH-AL vs MDS CV units)\u003c\/strong\u003e or explain \u003cstrong data-start=\"1599\" data-end=\"1693\"\u003ehow to check if this reactor is faulty in a CNC machine (overheating, trips, alarms, etc.)\u003c\/strong\u003e\u003c\/p\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45829486280840,"sku":"DH-AL-30K","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-05-16T130411.311.jpg?v=1778916860","url":"https:\/\/jjautomation.in\/products\/mitsubishi-m80-ac-reactor-dh-al-18-5k-copy","provider":"JJAutomation","version":"1.0","type":"link"}