{"product_id":"mitsubishi-m80-ac-reactor-dh-al-7-5k-copy","title":"Mitsubishi M80 AC Reactor DH-AL-11K","description":"\u003cp data-start=\"0\" data-end=\"175\"\u003eDH-AL-11K is a \u003cstrong data-start=\"15\" data-end=\"64\"\u003eMitsubishi Electric AC reactor (line reactor)\u003c\/strong\u003e used in CNC servo\/spindle drive power systems, especially with the \u003cstrong data-start=\"132\" data-end=\"174\"\u003eMDS-EH \/ MDS-DH series converter units\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3h1ku8\" data-start=\"177\" data-end=\"192\"\u003eDescription\u003c\/h3\u003e\n\u003cul data-start=\"193\" data-end=\"421\"\u003e\n\u003cli data-section-id=\"zwfwez\" data-start=\"193\" data-end=\"293\"\u003e\n\u003cstrong data-start=\"195\" data-end=\"212\"\u003eManufacturer:\u003c\/strong\u003e \u003ca data-start=\"213\" data-end=\"293\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.mitsubishielectric.com?utm_source=chatgpt.com\"\u003eMitsubishi Electric\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"175f3su\" data-start=\"294\" data-end=\"320\"\u003e\n\u003cstrong data-start=\"296\" data-end=\"307\"\u003eSeries:\u003c\/strong\u003e DH-AL series\u003c\/li\u003e\n\u003cli data-section-id=\"rang3b\" data-start=\"321\" data-end=\"343\"\u003e\n\u003cstrong data-start=\"323\" data-end=\"333\"\u003eModel:\u003c\/strong\u003e DH-AL-11K\u003c\/li\u003e\n\u003cli data-section-id=\"1v9cdbl\" data-start=\"344\" data-end=\"387\"\u003e\n\u003cstrong data-start=\"346\" data-end=\"355\"\u003eType:\u003c\/strong\u003e AC Reactor (Input line reactor)\u003c\/li\u003e\n\u003cli data-section-id=\"18zzgk2\" data-start=\"388\" data-end=\"421\"\u003e\n\u003cstrong data-start=\"390\" data-end=\"409\"\u003eRated Capacity:\u003c\/strong\u003e 11 kW class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1xnyxh\" data-start=\"423\" data-end=\"445\"\u003ePurpose \/ Function\u003c\/h3\u003e\n\u003cp data-start=\"446\" data-end=\"533\"\u003eThe DH-AL-11K is an \u003cstrong data-start=\"466\" data-end=\"503\"\u003eauxiliary power quality component\u003c\/strong\u003e, not a drive or power supply.\u003c\/p\u003e\n\u003cp data-start=\"535\" data-end=\"549\"\u003eIt is used to:\u003c\/p\u003e\n\u003cul data-start=\"550\" data-end=\"792\"\u003e\n\u003cli data-section-id=\"o37kbm\" data-start=\"550\" data-end=\"603\"\u003eReduce current harmonics from CNC converter units\u003c\/li\u003e\n\u003cli data-section-id=\"1g8kmr6\" data-start=\"604\" data-end=\"644\"\u003eLimit inrush current during power ON\u003c\/li\u003e\n\u003cli data-section-id=\"15vckut\" data-start=\"645\" data-end=\"697\"\u003eProtect the MDS power supply (rectifier section)\u003c\/li\u003e\n\u003cli data-section-id=\"6w09q0\" data-start=\"698\" data-end=\"742\"\u003eImprove input power factor and stability\u003c\/li\u003e\n\u003cli data-section-id=\"151gkl8\" data-start=\"743\" data-end=\"792\"\u003eReduce stress and heating in the drive system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1hkko7f\" data-start=\"794\" data-end=\"814\"\u003eWhere it is used\u003c\/h3\u003e\n\u003cp data-start=\"815\" data-end=\"837\"\u003eTypically paired with:\u003c\/p\u003e\n\u003cul data-start=\"838\" data-end=\"917\"\u003e\n\u003cli data-section-id=\"129qfxz\" data-start=\"838\" data-end=\"857\"\u003e\u003cstrong data-start=\"840\" data-end=\"857\"\u003eMDS-EH-CV-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1x5e5yu\" data-start=\"858\" data-end=\"917\"\u003eCNC spindle\/servo power supply systems around 11 kW class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1xevv0n\" data-start=\"919\" data-end=\"951\"\u003eElectrical Ratings (typical)\u003c\/h3\u003e\n\u003cul data-start=\"952\" data-end=\"1106\"\u003e\n\u003cli data-section-id=\"1cuqk64\" data-start=\"952\" data-end=\"981\"\u003e\n\u003cstrong data-start=\"954\" data-end=\"973\"\u003eRated capacity:\u003c\/strong\u003e 11 kW\u003c\/li\u003e\n\u003cli data-section-id=\"1s00jtt\" data-start=\"982\" data-end=\"1010\"\u003e\n\u003cstrong data-start=\"984\" data-end=\"1002\"\u003eRated current:\u003c\/strong\u003e ~21 A\u003c\/li\u003e\n\u003cli data-section-id=\"1tm0m23\" data-start=\"1011\" data-end=\"1054\"\u003e\n\u003cstrong data-start=\"1013\" data-end=\"1031\"\u003eRated voltage:\u003c\/strong\u003e 380–480 VAC, 3-phase\u003c\/li\u003e\n\u003cli data-section-id=\"18xe814\" data-start=\"1055\" data-end=\"1082\"\u003e\n\u003cstrong data-start=\"1057\" data-end=\"1071\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"19mkj9m\" data-start=\"1083\" data-end=\"1106\"\u003e\n\u003cstrong data-start=\"1085\" data-end=\"1096\"\u003eWeight:\u003c\/strong\u003e ~3.7 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yjfzv9\" data-start=\"1108\" data-end=\"1137\"\u003eSystem role (simple view)\u003c\/h3\u003e\n\u003cp data-start=\"1138\" data-end=\"1231\"\u003eAC mains → \u003cstrong data-start=\"1149\" data-end=\"1170\"\u003eDH-AL-11K reactor\u003c\/strong\u003e → MDS-EH-CV-110 power supply → DC bus → servo\/spindle drives\u003c\/p\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45829476778120,"sku":"DH-AL-11K","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-05-16T130411.311.jpg?v=1778916860","url":"https:\/\/jjautomation.in\/products\/mitsubishi-m80-ac-reactor-dh-al-7-5k-copy","provider":"JJAutomation","version":"1.0","type":"link"}