{"product_id":"mitsubishi-m80-power-supply-mds-eh-cv-750-copy","title":"Mitsubishi M80 AC Reactor DH-AL-7.5K","description":"\u003cdiv class=\"\" data-turn-id-container=\"0dd911d4-219c-45c4-9487-b845192d42af\" data-is-intersecting=\"true\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\" dir=\"auto\" data-turn-id=\"0dd911d4-219c-45c4-9487-b845192d42af\" data-turn-id-container=\"0dd911d4-219c-45c4-9487-b845192d42af\" data-testid=\"conversation-turn-17\" data-scroll-anchor=\"false\" data-turn=\"user\"\u003e\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-WEB:00055c7e-80e9-4385-98c8-4704170c4d92-8\" data-is-intersecting=\"true\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:00055c7e-80e9-4385-98c8-4704170c4d92-8\" data-turn-id-container=\"request-WEB:00055c7e-80e9-4385-98c8-4704170c4d92-8\" data-testid=\"conversation-turn-18\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-3 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"dbc71c5d-8219-494e-b084-483821485fdd\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"0\" data-end=\"99\"\u003eDH-AL-7.5K is a \u003cstrong data-start=\"16\" data-end=\"65\"\u003eMitsubishi Electric AC reactor (line reactor)\u003c\/strong\u003e used in CNC power supply systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3h1ku8\" data-start=\"101\" data-end=\"116\"\u003eDescription\u003c\/h3\u003e\n\u003cul data-start=\"117\" data-end=\"376\"\u003e\n\u003cli data-section-id=\"zwfwez\" data-start=\"117\" data-end=\"217\"\u003e\n\u003cstrong data-start=\"119\" data-end=\"136\"\u003eManufacturer:\u003c\/strong\u003e \u003ca data-start=\"137\" data-end=\"217\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.mitsubishielectric.com?utm_source=chatgpt.com\"\u003eMitsubishi Electric\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n7ga6r\" data-start=\"218\" data-end=\"257\"\u003e\n\u003cstrong data-start=\"220\" data-end=\"231\"\u003eSeries:\u003c\/strong\u003e DH-AL series (400V class)\u003c\/li\u003e\n\u003cli data-section-id=\"1ce3517\" data-start=\"258\" data-end=\"281\"\u003e\n\u003cstrong data-start=\"260\" data-end=\"270\"\u003eModel:\u003c\/strong\u003e DH-AL-7.5K\u003c\/li\u003e\n\u003cli data-section-id=\"e52a2r\" data-start=\"282\" data-end=\"341\"\u003e\n\u003cstrong data-start=\"284\" data-end=\"293\"\u003eType:\u003c\/strong\u003e AC Reactor (input reactor for CNC drive system)\u003c\/li\u003e\n\u003cli data-section-id=\"1a6ivz2\" data-start=\"342\" data-end=\"376\"\u003e\n\u003cstrong data-start=\"344\" data-end=\"363\"\u003eRated Capacity:\u003c\/strong\u003e 7.5 kW class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1xnyxh\" data-start=\"378\" data-end=\"400\"\u003ePurpose \/ Function\u003c\/h3\u003e\n\u003cp data-start=\"401\" data-end=\"537\"\u003eThe DH-AL-7.5K is \u003cstrong data-start=\"419\" data-end=\"446\"\u003enot a drive or inverter\u003c\/strong\u003e. It is a \u003cstrong data-start=\"456\" data-end=\"491\"\u003esupporting electrical component\u003c\/strong\u003e installed in front of CNC power supply units.\u003c\/p\u003e\n\u003cp data-start=\"539\" data-end=\"553\"\u003eIt is used to:\u003c\/p\u003e\n\u003cul data-start=\"554\" data-end=\"819\"\u003e\n\u003cli data-section-id=\"1nt33w1\" data-start=\"554\" data-end=\"602\"\u003eReduce harmonic distortion in the power line\u003c\/li\u003e\n\u003cli data-section-id=\"1g8kmr6\" data-start=\"603\" data-end=\"643\"\u003eLimit inrush current during power ON\u003c\/li\u003e\n\u003cli data-section-id=\"1epwkx8\" data-start=\"644\" data-end=\"711\"\u003eProtect rectifier\/converter units (like MDS-DH\/MDS-EH CV units)\u003c\/li\u003e\n\u003cli data-section-id=\"1qos4ro\" data-start=\"712\" data-end=\"766\"\u003eImprove overall power quality and system stability\u003c\/li\u003e\n\u003cli data-section-id=\"ao187y\" data-start=\"767\" data-end=\"819\"\u003eReduce electrical noise and stress on components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1hkko7f\" data-start=\"821\" data-end=\"841\"\u003eWhere it is used\u003c\/h3\u003e\n\u003cp data-start=\"842\" data-end=\"912\"\u003eIt is typically paired with Mitsubishi CNC power supply units such as:\u003c\/p\u003e\n\u003cul data-start=\"913\" data-end=\"996\"\u003e\n\u003cli data-section-id=\"f62kjv\" data-start=\"913\" data-end=\"950\"\u003eMDS-DH-CV series (400V CNC systems)\u003c\/li\u003e\n\u003cli data-section-id=\"f18lm\" data-start=\"951\" data-end=\"996\"\u003eMDS-EH-CV series (older MELDAS CNC systems)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"yxdv11\" data-start=\"998\" data-end=\"1022\"\u003eMatching Power Range\u003c\/h3\u003e\n\u003cul data-start=\"1023\" data-end=\"1223\"\u003e\n\u003cli data-section-id=\"s88030\" data-start=\"1023\" data-end=\"1060\"\u003e7.5 kW class power supply systems\u003c\/li\u003e\n\u003cli data-section-id=\"1h7rat2\" data-start=\"1061\" data-end=\"1113\"\u003eUsed in smaller CNC spindle\/servo configurations\u003c\/li\u003e\n\u003cli data-section-id=\"x7h09d\" data-start=\"1114\" data-end=\"1223\"\u003eIn the same family, higher sizes include 11K, 18.5K, 30K, 37K, etc. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17uthwx\" data-start=\"1225\" data-end=\"1263\"\u003eWhat it looks like in system terms\u003c\/h3\u003e\n\u003cp data-start=\"1264\" data-end=\"1361\"\u003eAC Supply → \u003cstrong data-start=\"1276\" data-end=\"1300\"\u003eDH-AL-7.5K (reactor)\u003c\/strong\u003e → MDS Power Supply (CV unit) → DC Bus → Servo\/Spindle Drives\u003c\/p\u003e\n\u003ch3 data-section-id=\"qmgkpp\" data-start=\"1363\" data-end=\"1376\"\u003eKey point\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul data-start=\"1377\" data-end=\"1481\"\u003e\n\u003cli data-section-id=\"ml8rbd\" data-start=\"1377\" data-end=\"1409\"\u003eIt does \u003cstrong data-start=\"1387\" data-end=\"1409\"\u003enot generate power\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cieqnx\" data-start=\"1410\" data-end=\"1481\"\u003eIt is a \u003cstrong data-start=\"1420\" data-end=\"1456\"\u003eprotection + filtering component\u003c\/strong\u003e for CNC drive input side\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45829391548552,"sku":"DH-AL-7.5K","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-05-16T130411.311.jpg?v=1778916860","url":"https:\/\/jjautomation.in\/products\/mitsubishi-m80-power-supply-mds-eh-cv-750-copy","provider":"JJAutomation","version":"1.0","type":"link"}