{"product_id":"siemens-motor-reactor-6se7021-0es87-1fe0","title":"SIEMENS Motor Reactor 6SE7021-0ES87-1FE0","description":"\u003ch2 data-section-id=\"1bw7wp4\" data-start=\"301\" data-end=\"323\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"325\" data-end=\"841\"\u003eThe Siemens 6SE7021-0ES87-1FE0 is a high-performance braking resistor engineered for use with SIMOVERT MASTERDRIVES and compatible Siemens drive systems. Designed to dissipate regenerative energy generated during motor deceleration, this resistor helps protect the DC-link from overvoltage conditions while ensuring stable and reliable drive operation. With a resistance value of 40 Ω and a rated braking power of 6.25 kW, it provides efficient energy absorption for demanding industrial motion control applications.\u003c\/p\u003e\n\u003cp data-start=\"843\" data-end=\"1127\"\u003eBuilt for continuous operation in industrial environments, the resistor is ideal for machine tools, cranes, conveyors, material handling systems, packaging machinery, printing equipment, and automated production lines where frequent braking cycles and rapid deceleration are required.\u003c\/p\u003e\n\u003chr data-start=\"1129\" data-end=\"1132\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1134\" data-end=\"1149\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1151\" data-end=\"1592\"\u003e\n\u003cli data-section-id=\"136cpp6\" data-start=\"1151\" data-end=\"1207\"\u003eGenuine Siemens SIMOVERT MASTERDRIVES braking resistor\u003c\/li\u003e\n\u003cli data-section-id=\"d1cjgo\" data-start=\"1208\" data-end=\"1254\"\u003eDesigned for regenerative energy dissipation\u003c\/li\u003e\n\u003cli data-section-id=\"9uoac7\" data-start=\"1255\" data-end=\"1279\"\u003eResistance value: 40 Ω\u003c\/li\u003e\n\u003cli data-section-id=\"1usw4ky\" data-start=\"1280\" data-end=\"1310\"\u003eRated braking power: 6.25 kW\u003c\/li\u003e\n\u003cli data-section-id=\"qd5wk4\" data-start=\"1311\" data-end=\"1358\"\u003eCompatible with SIMOVERT MASTERDRIVES systems\u003c\/li\u003e\n\u003cli data-section-id=\"1a9j5pt\" data-start=\"1359\" data-end=\"1406\"\u003eProtects DC-link circuits against overvoltage\u003c\/li\u003e\n\u003cli data-section-id=\"2gsckg\" data-start=\"1407\" data-end=\"1443\"\u003eHeavy-duty industrial construction\u003c\/li\u003e\n\u003cli data-section-id=\"fw3kck\" data-start=\"1444\" data-end=\"1487\"\u003eSuitable for dynamic braking applications\u003c\/li\u003e\n\u003cli data-section-id=\"c7cjho\" data-start=\"1488\" data-end=\"1540\"\u003eReliable operation under demanding load conditions\u003c\/li\u003e\n\u003cli data-section-id=\"p9dl38\" data-start=\"1541\" data-end=\"1592\"\u003eEasy integration into Siemens drive architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1594\" data-end=\"1597\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1599\" data-end=\"1626\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1628\" data-end=\"2230\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1628\" data-end=\"1655\"\u003e\n\u003ctr data-start=\"1628\" data-end=\"1655\"\u003e\n\u003cth data-start=\"1628\" data-end=\"1644\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1644\" data-end=\"1655\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1683\" data-end=\"2230\"\u003e\n\u003ctr data-start=\"1683\" data-end=\"1709\"\u003e\n\u003ctd data-start=\"1683\" data-end=\"1698\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"1698\" data-end=\"1709\" data-col-size=\"sm\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1710\" data-end=\"1746\"\u003e\n\u003ctd data-start=\"1710\" data-end=\"1724\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-start=\"1724\" data-end=\"1746\" data-col-size=\"sm\"\u003e6SE7021-0ES87-1FE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1747\" data-end=\"1789\"\u003e\n\u003ctd data-start=\"1747\" data-end=\"1764\" data-col-size=\"sm\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-start=\"1764\" data-end=\"1789\" data-col-size=\"sm\"\u003eSIMOVERT MASTERDRIVES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1790\" data-end=\"1825\"\u003e\n\u003ctd data-start=\"1790\" data-end=\"1805\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"1805\" data-end=\"1825\" data-col-size=\"sm\"\u003eBraking Resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1826\" data-end=\"1853\"\u003e\n\u003ctd data-start=\"1826\" data-end=\"1845\" data-col-size=\"sm\"\u003eResistance Value\u003c\/td\u003e\n\u003ctd data-start=\"1845\" data-end=\"1853\" data-col-size=\"sm\"\u003e40 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1854\" data-end=\"1887\"\u003e\n\u003ctd data-start=\"1854\" data-end=\"1876\" data-col-size=\"sm\"\u003eRated Braking Power\u003c\/td\u003e\n\u003ctd data-start=\"1876\" data-end=\"1887\" data-col-size=\"sm\"\u003e6.25 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1888\" data-end=\"1920\"\u003e\n\u003ctd data-start=\"1888\" data-end=\"1904\" data-col-size=\"sm\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-start=\"1904\" data-end=\"1920\" data-col-size=\"sm\"\u003e510–620 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1921\" data-end=\"1961\"\u003e\n\u003ctd data-start=\"1921\" data-end=\"1938\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-start=\"1938\" data-end=\"1961\" data-col-size=\"sm\"\u003eNatural Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1962\" data-end=\"1989\"\u003e\n\u003ctd data-start=\"1962\" data-end=\"1981\" data-col-size=\"sm\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-start=\"1981\" data-end=\"1989\" data-col-size=\"sm\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1990\" data-end=\"2031\"\u003e\n\u003ctd data-start=\"1990\" data-end=\"2006\" data-col-size=\"sm\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd data-start=\"2006\" data-end=\"2031\" data-col-size=\"sm\"\u003ePanel \/ Cabinet Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2032\" data-end=\"2081\"\u003e\n\u003ctd data-start=\"2032\" data-end=\"2046\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2046\" data-end=\"2081\" data-col-size=\"sm\"\u003eRegenerative Energy Dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2082\" data-end=\"2130\"\u003e\n\u003ctd data-start=\"2082\" data-end=\"2105\" data-col-size=\"sm\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-start=\"2105\" data-end=\"2130\" data-col-size=\"sm\"\u003eSIMOVERT MASTERDRIVES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2131\" data-end=\"2183\"\u003e\n\u003ctd data-start=\"2131\" data-end=\"2151\" data-col-size=\"sm\"\u003eProduct Lifecycle\u003c\/td\u003e\n\u003ctd data-start=\"2151\" data-end=\"2183\" data-col-size=\"sm\"\u003eActive \/ Spare Parts Support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2184\" data-end=\"2230\"\u003e\n\u003ctd data-start=\"2184\" data-end=\"2196\" data-col-size=\"sm\"\u003eCondition\u003c\/td\u003e\n\u003ctd data-start=\"2196\" data-end=\"2230\" data-col-size=\"sm\"\u003eNew \/ Original Siemens Product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2232\" data-end=\"2235\"\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"2237\" data-end=\"2252\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"2254\" data-end=\"2501\"\u003e\n\u003cli data-section-id=\"15zr0f0\" data-start=\"2254\" data-end=\"2291\"\u003eSIMOVERT MASTERDRIVES Drive Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1wjktfk\" data-start=\"2292\" data-end=\"2327\"\u003eIndustrial Motion Control Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1wm1u94\" data-start=\"2328\" data-end=\"2347\"\u003eCNC Machine Tools\u003c\/li\u003e\n\u003cli data-section-id=\"1uff8fc\" data-start=\"2348\" data-end=\"2379\"\u003eCranes and Hoisting Equipment\u003c\/li\u003e\n\u003cli data-section-id=\"lnxerv\" data-start=\"2380\" data-end=\"2398\"\u003eConveyor Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1h8adgm\" data-start=\"2399\" data-end=\"2428\"\u003eMaterial Handling Equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1dkgd5l\" data-start=\"2429\" data-end=\"2450\"\u003ePackaging Machinery\u003c\/li\u003e\n\u003cli data-section-id=\"mszwug\" data-start=\"2451\" data-end=\"2469\"\u003ePrinting Presses\u003c\/li\u003e\n\u003cli data-section-id=\"bnhczn\" data-start=\"2470\" data-end=\"2501\"\u003eAutomated Manufacturing Lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2503\" data-end=\"2506\"\u003e\n\u003ch2 data-section-id=\"2qq1z5\" data-start=\"2508\" data-end=\"2519\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"2521\" data-end=\"2824\"\u003e\n\u003cli data-section-id=\"1ggfekr\" data-start=\"2521\" data-end=\"2560\"\u003eEfficiently dissipates braking energy\u003c\/li\u003e\n\u003cli data-section-id=\"18zzte2\" data-start=\"2561\" data-end=\"2598\"\u003ePrevents DC-link overvoltage faults\u003c\/li\u003e\n\u003cli data-section-id=\"x1ev2b\" data-start=\"2599\" data-end=\"2645\"\u003eImproves drive system reliability and uptime\u003c\/li\u003e\n\u003cli data-section-id=\"1jg4cm6\" data-start=\"2646\" data-end=\"2688\"\u003eSupports high-dynamic braking operations\u003c\/li\u003e\n\u003cli data-section-id=\"41yxi2\" data-start=\"2689\" data-end=\"2725\"\u003eReduces stress on drive components\u003c\/li\u003e\n\u003cli data-section-id=\"8adh9\" data-start=\"2726\" data-end=\"2772\"\u003eSuitable for continuous industrial operation\u003c\/li\u003e\n\u003cli data-section-id=\"1pm7lvi\" data-start=\"2773\" data-end=\"2824\"\u003eGenuine Siemens quality for long-term performance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":46115835445384,"sku":"6SE7021-0ES87-1FE0","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/jjautomation-three-phase-line-reactor-x7r29k_04d3e5a9-24d1-474c-a57e-4f22308dada3.jpg?v=1781593240","url":"https:\/\/jjautomation.in\/products\/siemens-motor-reactor-6se7021-0es87-1fe0","provider":"JJAutomation","version":"1.0","type":"link"}