{"product_id":"sinamics-24-v-terminal-adapter-6sl3162-2aa00-0aa0-copy","title":"SINAMICS 24 V Jumper 6SL3162-2AA01-0AA0","description":"\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" class=\"\"\u003e\n\u003csection data-turn=\"user\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-141\" data-turn-id-container=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" data-turn-id=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\"\u003e\u003c\/section\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"c451786a-7273-4ee6-a017-8265568ed51e\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\" dir=\"auto\" data-turn-id=\"c451786a-7273-4ee6-a017-8265568ed51e\" data-turn-id-container=\"c451786a-7273-4ee6-a017-8265568ed51e\" data-testid=\"conversation-turn-159\" data-scroll-anchor=\"false\" data-turn=\"user\"\u003e\u003c\/section\u003e\n\u003ch2 data-section-id=\"1h8dzc0\" data-start=\"0\" data-end=\"60\"\u003eSiemens 6SL3162-2AA01-0AA0 – SINAMICS 24 V Plug-In Jumper\u003c\/h2\u003e\n\u003cp data-start=\"62\" data-end=\"401\"\u003eThe \u003cstrong data-start=\"66\" data-end=\"96\"\u003eSiemens 6SL3162-2AA01-0AA0\u003c\/strong\u003e is a \u003cstrong data-start=\"102\" data-end=\"151\"\u003eSINAMICS S120 replacement 24 V plug-in jumper\u003c\/strong\u003e designed for \u003cstrong data-start=\"165\" data-end=\"185\"\u003eBooksize modules\u003c\/strong\u003e. It is an accessory used to connect the \u003cstrong data-start=\"226\" data-end=\"242\"\u003e24 V busbars\u003c\/strong\u003e between SINAMICS S120 modules, ensuring reliable distribution of the control supply voltage throughout the drive system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"403\" data-end=\"406\"\u003e\n\u003ch3 data-section-id=\"hc1qto\" data-start=\"408\" data-end=\"435\"\u003e🔧 Basic Identification\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"437\" data-end=\"789\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"437\" data-end=\"458\"\u003e\n\u003ctr data-start=\"437\" data-end=\"458\"\u003e\n\u003cth data-start=\"437\" data-end=\"447\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"447\" data-end=\"458\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"469\" data-end=\"789\"\u003e\n\u003ctr data-start=\"469\" data-end=\"525\"\u003e\n\u003ctd data-start=\"469\" data-end=\"484\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"484\" data-end=\"525\" data-col-size=\"sm\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003ca class=\"decorated-link\" rel=\"noopener\" href=\"https:\/\/www.siemens.com?utm_source=chatgpt.com\" target=\"_blank\"\u003eSiemens\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"526\" data-end=\"560\"\u003e\n\u003ctd data-start=\"526\" data-end=\"543\" data-col-size=\"sm\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-start=\"543\" data-end=\"560\" data-col-size=\"sm\"\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"561\" data-end=\"597\"\u003e\n\u003ctd data-start=\"561\" data-end=\"575\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-start=\"575\" data-end=\"597\" data-col-size=\"sm\"\u003e6SL3162-2AA01-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"598\" data-end=\"636\"\u003e\n\u003ctd data-start=\"598\" data-end=\"613\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"613\" data-end=\"636\" data-col-size=\"sm\"\u003e24 V Plug-In Jumper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"637\" data-end=\"677\"\u003e\n\u003ctd data-start=\"637\" data-end=\"651\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"651\" data-end=\"677\" data-col-size=\"sm\"\u003e24 V Busbar Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"678\" data-end=\"732\"\u003e\n\u003ctd data-start=\"678\" data-end=\"698\" data-col-size=\"sm\"\u003eCompatible System\u003c\/td\u003e\n\u003ctd data-start=\"698\" data-end=\"732\" data-col-size=\"sm\"\u003eSINAMICS S120 Booksize Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"733\" data-end=\"760\"\u003e\n\u003ctd data-start=\"733\" data-end=\"749\" data-col-size=\"sm\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd data-start=\"749\" data-end=\"760\" data-col-size=\"sm\"\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"761\" data-end=\"789\"\u003e\n\u003ctd data-start=\"761\" data-end=\"778\" data-col-size=\"sm\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd data-start=\"778\" data-end=\"789\" data-col-size=\"sm\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"791\" data-end=\"937\"\u003e📌 Siemens describes this accessory as a \u003cstrong data-start=\"832\" data-end=\"898\"\u003ereplacement 24 V plug-in jumper for modules in Booksize design\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"939\" data-end=\"942\"\u003e\n\u003ch3 data-section-id=\"hfo6i2\" data-start=\"944\" data-end=\"965\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cp data-start=\"967\" data-end=\"1005\"\u003eThe 6SL3162-2AA01-0AA0 is designed to:\u003c\/p\u003e\n\u003cul data-start=\"1007\" data-end=\"1347\"\u003e\n\u003cli data-section-id=\"16w2hke\" data-start=\"1007\" data-end=\"1068\"\u003eConnect 24 V busbars between SINAMICS S120 Booksize modules\u003c\/li\u003e\n\u003cli data-section-id=\"1xvytg1\" data-start=\"1069\" data-end=\"1125\"\u003eDistribute control voltage throughout the drive lineup\u003c\/li\u003e\n\u003cli data-section-id=\"6zkdi7\" data-start=\"1126\" data-end=\"1165\"\u003eSimplify installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"vaqlas\" data-start=\"1166\" data-end=\"1202\"\u003eReplace damaged or missing jumpers\u003c\/li\u003e\n\u003cli data-section-id=\"101zfau\" data-start=\"1203\" data-end=\"1255\"\u003eEnsure reliable power supply to module electronics\u003c\/li\u003e\n\u003cli data-section-id=\"1e157jl\" data-start=\"1256\" data-end=\"1347\"\u003eSupport modular SINAMICS S120 system configurations \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1349\" data-end=\"1352\"\u003e\n\u003ch3 data-section-id=\"12k99m5\" data-start=\"1354\" data-end=\"1385\"\u003e📋 Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1387\" data-end=\"1668\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1387\" data-end=\"1412\"\u003e\n\u003ctr data-start=\"1387\" data-end=\"1412\"\u003e\n\u003cth data-start=\"1387\" data-end=\"1403\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1403\" data-end=\"1412\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1423\" data-end=\"1668\"\u003e\n\u003ctr data-start=\"1423\" data-end=\"1461\"\u003e\n\u003ctd data-start=\"1423\" data-end=\"1438\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"1438\" data-end=\"1461\" data-col-size=\"sm\"\u003e24 V Plug-In Jumper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1462\" data-end=\"1489\"\u003e\n\u003ctd data-start=\"1462\" data-end=\"1478\" data-col-size=\"sm\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd data-start=\"1478\" data-end=\"1489\" data-col-size=\"sm\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1490\" data-end=\"1518\"\u003e\n\u003ctd data-start=\"1490\" data-end=\"1507\" data-col-size=\"sm\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1507\" data-end=\"1518\"\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1519\" data-end=\"1566\"\u003e\n\u003ctd data-start=\"1519\" data-end=\"1540\" data-col-size=\"sm\"\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd data-start=\"1540\" data-end=\"1566\" data-col-size=\"sm\"\u003eSINAMICS S120 Booksize\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1567\" data-end=\"1598\"\u003e\n\u003ctd data-start=\"1567\" data-end=\"1586\" data-col-size=\"sm\"\u003ePackage Quantity\u003c\/td\u003e\n\u003ctd data-start=\"1586\" data-end=\"1598\" data-col-size=\"sm\"\u003e5 Pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1599\" data-end=\"1627\"\u003e\n\u003ctd data-start=\"1599\" data-end=\"1608\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"1608\" data-end=\"1627\" data-col-size=\"sm\"\u003eApprox. 0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1628\" data-end=\"1668\"\u003e\n\u003ctd data-start=\"1628\" data-end=\"1652\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"1652\" data-end=\"1668\" data-col-size=\"sm\"\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1670\" data-end=\"1793\"\u003eTechnical specifications are listed by Siemens distributors and automation suppliers. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1795\" data-end=\"1798\"\u003e\n\u003ch3 data-section-id=\"zb3ky1\" data-start=\"1800\" data-end=\"1818\"\u003e🧠 System Role\u003c\/h3\u003e\n\u003cp data-start=\"1820\" data-end=\"1852\"\u003eIn a SINAMICS S120 drive system:\u003c\/p\u003e\n\u003cp data-start=\"1854\" data-end=\"1968\"\u003e\u003cstrong data-start=\"1854\" data-end=\"1875\"\u003e24 V Power Supply\u003c\/strong\u003e\u003cbr data-start=\"1875\" data-end=\"1878\"\u003e→ \u003cstrong data-start=\"1880\" data-end=\"1917\"\u003e6SL3162-2AA01-0AA0 Plug-In Jumper\u003c\/strong\u003e\u003cbr data-start=\"1917\" data-end=\"1920\"\u003e→ \u003cstrong data-start=\"1922\" data-end=\"1938\"\u003e24 V Busbars\u003c\/strong\u003e\u003cbr data-start=\"1938\" data-end=\"1941\"\u003e→ \u003cstrong data-start=\"1943\" data-end=\"1968\"\u003eSINAMICS S120 Modules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1970\" data-end=\"2147\"\u003eThe jumper serves as a \u003cstrong data-start=\"1993\" data-end=\"2027\"\u003e24 V interconnection accessory\u003c\/strong\u003e, allowing auxiliary control power to be shared between adjacent Booksize modules. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2149\" data-end=\"2152\"\u003e\n\u003ch3 data-section-id=\"1syspfw\" data-start=\"2154\" data-end=\"2199\"\u003e🔍 Difference Between Similar Accessories\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2201\" data-end=\"2323\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2201\" data-end=\"2221\"\u003e\n\u003ctr data-start=\"2201\" data-end=\"2221\"\u003e\n\u003cth data-start=\"2201\" data-end=\"2209\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"2209\" data-end=\"2221\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2232\" data-end=\"2323\"\u003e\n\u003ctr data-start=\"2232\" data-end=\"2278\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2253\" data-col-size=\"sm\"\u003e6SL3162-2AA00-0AA0\u003c\/td\u003e\n\u003ctd data-start=\"2253\" data-end=\"2278\" data-col-size=\"sm\"\u003e24 V Terminal Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2279\" data-end=\"2323\"\u003e\n\u003ctd data-start=\"2279\" data-end=\"2300\" data-col-size=\"sm\"\u003e6SL3162-2AA01-0AA0\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2300\" data-end=\"2323\"\u003e24 V Plug-In Jumper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"2325\" data-end=\"2557\"\u003eThe \u003cstrong data-start=\"2329\" data-end=\"2351\"\u003e6SL3162-2AA00-0AA0\u003c\/strong\u003e provides a connection point for an external 24 V DC supply, while the \u003cstrong data-start=\"2422\" data-end=\"2444\"\u003e6SL3162-2AA01-0AA0\u003c\/strong\u003e is used to bridge and distribute the 24 V supply between Booksize modules. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2559\" data-end=\"2562\"\u003e\n\u003ch3 data-section-id=\"1tre2jo\" data-start=\"2564\" data-end=\"2591\"\u003e🏭 Typical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2593\" data-end=\"2801\"\u003e\n\u003cli data-section-id=\"1dnkotk\" data-start=\"2593\" data-end=\"2612\"\u003eCNC machine tools\u003c\/li\u003e\n\u003cli data-section-id=\"k4khi8\" data-start=\"2613\" data-end=\"2643\"\u003eSINUMERIK-controlled systems\u003c\/li\u003e\n\u003cli data-section-id=\"g4wubk\" data-start=\"2644\" data-end=\"2660\"\u003eRobotics cells\u003c\/li\u003e\n\u003cli data-section-id=\"gxxvnd\" data-start=\"2661\" data-end=\"2682\"\u003ePackaging machinery\u003c\/li\u003e\n\u003cli data-section-id=\"p8897e\" data-start=\"2683\" data-end=\"2710\"\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli data-section-id=\"620cq0\" data-start=\"2711\" data-end=\"2743\"\u003eMulti-axis servo drive systems\u003c\/li\u003e\n\u003cli data-section-id=\"16pf8bx\" data-start=\"2744\" data-end=\"2801\"\u003eIndustrial automation panels using SINAMICS S120 drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2803\" data-end=\"2806\"\u003e\n\u003ch3 data-section-id=\"qeypbd\" data-start=\"2808\" data-end=\"2840\"\u003e🧾 Short Website Description\u003c\/h3\u003e\n\u003cp data-start=\"2842\" data-end=\"3194\"\u003eThe \u003cstrong data-start=\"2846\" data-end=\"2876\"\u003eSiemens 6SL3162-2AA01-0AA0\u003c\/strong\u003e is a SINAMICS S120 \u003cstrong data-start=\"2896\" data-end=\"2919\"\u003e24 V plug-in jumper\u003c\/strong\u003e designed for Booksize drive modules. It provides reliable interconnection of 24 V busbars between adjacent modules, ensuring consistent control power distribution throughout CNC, robotics, servo drive, and industrial automation systems.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45923501965448,"sku":"6SL3162-2AA01-0AA0","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-06-02T133243.503.jpg?v=1780387386","url":"https:\/\/jjautomation.in\/products\/sinamics-24-v-terminal-adapter-6sl3162-2aa00-0aa0-copy","provider":"JJAutomation","version":"1.0","type":"link"}