{"product_id":"sinamics-line-reactor-6sl3000-0ce22-0aa0-copy","title":"SINAMICS Line Reactor 6SL3000-0CE24-0AA0","description":"\u003ch3 data-section-id=\"1khm5ao\" data-start=\"0\" data-end=\"42\"\u003eSiemens 6SL3000-0CE24-0AA0 Description\u003c\/h3\u003e\n\u003cp data-start=\"44\" data-end=\"446\"\u003eThe \u003cstrong data-start=\"48\" data-end=\"78\"\u003eSiemens 6SL3000-0CE24-0AA0\u003c\/strong\u003e is a \u003cstrong data-start=\"84\" data-end=\"114\"\u003eSINAMICS S120 Line Reactor\u003c\/strong\u003e designed for use with \u003cstrong data-start=\"137\" data-end=\"171\"\u003e40 kW Basic Line Modules (BLM)\u003c\/strong\u003e in SINAMICS S120 drive systems. Operating on \u003cstrong data-start=\"217\" data-end=\"251\"\u003e3-phase 380–480 V AC, 50\/60 Hz\u003c\/strong\u003e, the reactor is installed between the mains supply and the Basic Line Module to reduce harmonic distortion, limit inrush currents, suppress voltage transients, and improve overall power quality.\u003c\/p\u003e\n\u003cp data-start=\"448\" data-end=\"927\"\u003eAs an essential line-side component of the SINAMICS S120 platform, the 6SL3000-0CE24-0AA0 provides the required impedance for proper operation of the Basic Line Module. It helps protect power electronics from electrical disturbances, reduces stress on rectifier components, improves electromagnetic compatibility (EMC), and enhances system reliability. By minimizing harmonics and current peaks, the reactor contributes to longer equipment life and more stable drive performance.\u003c\/p\u003e\n\u003cp data-start=\"929\" data-end=\"1198\"\u003eThe 6SL3000-0CE24-0AA0 is widely used in CNC machine tools, packaging machinery, robotics, printing systems, material handling equipment, conveyor systems, and industrial automation applications requiring reliable power conditioning for high-performance motion control.\u003c\/p\u003e\n\u003chr data-start=\"1200\" data-end=\"1203\"\u003e\n\u003ch3 data-section-id=\"hc1qto\" data-start=\"1205\" data-end=\"1232\"\u003e🔧 Basic Identification\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1234\" data-end=\"1601\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1234\" data-end=\"1255\"\u003e\n\u003ctr data-start=\"1234\" data-end=\"1255\"\u003e\n\u003cth data-start=\"1234\" data-end=\"1244\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1244\" data-end=\"1255\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1280\" data-end=\"1601\"\u003e\n\u003ctr data-start=\"1280\" data-end=\"1306\"\u003e\n\u003ctd data-start=\"1280\" data-end=\"1295\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1295\" data-end=\"1306\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1307\" data-end=\"1341\"\u003e\n\u003ctd data-start=\"1307\" data-end=\"1324\" data-col-size=\"sm\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-start=\"1324\" data-end=\"1341\" data-col-size=\"sm\"\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1342\" data-end=\"1378\"\u003e\n\u003ctd data-start=\"1342\" data-end=\"1356\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1356\" data-end=\"1378\"\u003e6SL3000-0CE24-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1379\" data-end=\"1410\"\u003e\n\u003ctd data-start=\"1379\" data-end=\"1394\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1394\" data-end=\"1410\"\u003eLine Reactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1411\" data-end=\"1452\"\u003e\n\u003ctd data-start=\"1411\" data-end=\"1425\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1425\" data-end=\"1452\"\u003eBasic Line Module (BLM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1453\" data-end=\"1488\"\u003e\n\u003ctd data-start=\"1453\" data-end=\"1479\" data-col-size=\"sm\"\u003eCompatible Power Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1479\" data-end=\"1488\"\u003e40 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1489\" data-end=\"1523\"\u003e\n\u003ctd data-start=\"1489\" data-end=\"1505\" data-col-size=\"sm\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1505\" data-end=\"1523\"\u003e3 AC 380–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1524\" data-end=\"1548\"\u003e\n\u003ctd data-start=\"1524\" data-end=\"1536\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1536\" data-end=\"1548\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1549\" data-end=\"1573\"\u003e\n\u003ctd data-start=\"1549\" data-end=\"1565\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1565\" data-end=\"1573\"\u003e67 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1574\" data-end=\"1601\"\u003e\n\u003ctd data-start=\"1574\" data-end=\"1593\" data-col-size=\"sm\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1593\" data-end=\"1601\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1603\" data-end=\"1606\"\u003e\n\u003ch3 data-section-id=\"hfo6i2\" data-start=\"1608\" data-end=\"1629\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"1631\" data-end=\"1962\"\u003e\n\u003cli data-section-id=\"1cedhz2\" data-start=\"1631\" data-end=\"1680\"\u003eReduces harmonic distortion on the mains supply\u003c\/li\u003e\n\u003cli data-section-id=\"zrz0yp\" data-start=\"1681\" data-end=\"1717\"\u003eLimits startup and inrush currents\u003c\/li\u003e\n\u003cli data-section-id=\"12yi0o6\" data-start=\"1718\" data-end=\"1771\"\u003eProtects Basic Line Modules from voltage transients\u003c\/li\u003e\n\u003cli data-section-id=\"1nu4bq5\" data-start=\"1772\" data-end=\"1818\"\u003eImproves electromagnetic compatibility (EMC)\u003c\/li\u003e\n\u003cli data-section-id=\"1ap63lp\" data-start=\"1819\" data-end=\"1866\"\u003eEnhances power quality and system reliability\u003c\/li\u003e\n\u003cli data-section-id=\"u8tuqv\" data-start=\"1867\" data-end=\"1914\"\u003eReduces electrical stress on power components\u003c\/li\u003e\n\u003cli data-section-id=\"g86sox\" data-start=\"1915\" data-end=\"1962\"\u003eSupports stable SINAMICS S120 drive operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1964\" data-end=\"1967\"\u003e\n\u003ch3 data-section-id=\"12k99m5\" data-start=\"1969\" data-end=\"2000\"\u003e📋 Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2002\" data-end=\"2358\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2002\" data-end=\"2027\"\u003e\n\u003ctr data-start=\"2002\" data-end=\"2027\"\u003e\n\u003cth data-start=\"2002\" data-end=\"2018\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2018\" data-end=\"2027\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2038\" data-end=\"2358\"\u003e\n\u003ctr data-start=\"2038\" data-end=\"2069\"\u003e\n\u003ctd data-start=\"2038\" data-end=\"2053\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2053\" data-end=\"2069\" data-col-size=\"sm\"\u003eLine Reactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2070\" data-end=\"2117\"\u003e\n\u003ctd data-start=\"2070\" data-end=\"2090\" data-col-size=\"sm\"\u003eCompatible Module\u003c\/td\u003e\n\u003ctd data-start=\"2090\" data-end=\"2117\" data-col-size=\"sm\"\u003e40 kW Basic Line Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2118\" data-end=\"2153\"\u003e\n\u003ctd data-start=\"2118\" data-end=\"2135\" data-col-size=\"sm\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2135\" data-end=\"2153\" data-col-size=\"sm\"\u003e3 AC 380–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2154\" data-end=\"2184\"\u003e\n\u003ctd data-start=\"2154\" data-end=\"2172\" data-col-size=\"sm\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd data-start=\"2172\" data-end=\"2184\" data-col-size=\"sm\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2185\" data-end=\"2209\"\u003e\n\u003ctd data-start=\"2185\" data-end=\"2201\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2201\" data-end=\"2209\"\u003e67 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2210\" data-end=\"2238\"\u003e\n\u003ctd data-start=\"2210\" data-end=\"2230\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2230\" data-end=\"2238\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2239\" data-end=\"2279\"\u003e\n\u003ctd data-start=\"2239\" data-end=\"2256\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-start=\"2256\" data-end=\"2279\" data-col-size=\"sm\"\u003eNatural Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2280\" data-end=\"2324\"\u003e\n\u003ctd data-start=\"2280\" data-end=\"2296\" data-col-size=\"sm\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd data-start=\"2296\" data-end=\"2324\" data-col-size=\"sm\"\u003eCabinet \/ Panel Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2325\" data-end=\"2358\"\u003e\n\u003ctd data-start=\"2325\" data-end=\"2341\" data-col-size=\"sm\"\u003eSystem Family\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2341\" data-end=\"2358\"\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2360\" data-end=\"2363\"\u003e\n\u003ch3 data-section-id=\"zb3ky1\" data-start=\"2365\" data-end=\"2383\"\u003e🧠 System Role\u003c\/h3\u003e\n\u003cp data-start=\"2385\" data-end=\"2417\"\u003eIn a SINAMICS S120 architecture:\u003c\/p\u003e\n\u003cp data-start=\"2419\" data-end=\"2593\"\u003e\u003cstrong data-start=\"2419\" data-end=\"2439\"\u003e3-Phase AC Mains\u003c\/strong\u003e\u003cbr data-start=\"2439\" data-end=\"2442\"\u003e→ \u003cstrong data-start=\"2444\" data-end=\"2479\"\u003e6SL3000-0CE24-0AA0 Line Reactor\u003c\/strong\u003e\u003cbr data-start=\"2479\" data-end=\"2482\"\u003e→ \u003cstrong data-start=\"2484\" data-end=\"2511\"\u003e40 kW Basic Line Module\u003c\/strong\u003e\u003cbr data-start=\"2511\" data-end=\"2514\"\u003e→ \u003cstrong data-start=\"2516\" data-end=\"2533\"\u003e600 V DC Link\u003c\/strong\u003e\u003cbr data-start=\"2533\" data-end=\"2536\"\u003e→ \u003cstrong data-start=\"2538\" data-end=\"2555\"\u003eMotor Modules\u003c\/strong\u003e\u003cbr data-start=\"2555\" data-end=\"2558\"\u003e→ \u003cstrong data-start=\"2560\" data-end=\"2593\"\u003eServo Motors \/ Spindle Motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2595\" data-end=\"2778\"\u003eThe line reactor conditions incoming power and provides the line-side impedance required for reliable Basic Line Module operation while reducing harmonics and electrical disturbances.\u003c\/p\u003e\n\u003chr data-start=\"2780\" data-end=\"2783\"\u003e\n\u003ch3 data-section-id=\"1tre2jo\" data-start=\"2785\" data-end=\"2812\"\u003e🏭 Typical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2814\" data-end=\"3050\"\u003e\n\u003cli data-section-id=\"6siw3i\" data-start=\"2814\" data-end=\"2837\"\u003eCNC machining centers\u003c\/li\u003e\n\u003cli data-section-id=\"13thph4\" data-start=\"2838\" data-end=\"2874\"\u003eSINUMERIK-controlled machine tools\u003c\/li\u003e\n\u003cli data-section-id=\"gxxvnd\" data-start=\"2875\" data-end=\"2896\"\u003ePackaging machinery\u003c\/li\u003e\n\u003cli data-section-id=\"1n0v9gj\" data-start=\"2897\" data-end=\"2915\"\u003eRobotics systems\u003c\/li\u003e\n\u003cli data-section-id=\"8usc4m\" data-start=\"2916\" data-end=\"2945\"\u003eMaterial handling equipment\u003c\/li\u003e\n\u003cli data-section-id=\"7q2k7n\" data-start=\"2946\" data-end=\"2980\"\u003ePrinting and converting machines\u003c\/li\u003e\n\u003cli data-section-id=\"ks4s2z\" data-start=\"2981\" data-end=\"2999\"\u003eConveyor systems\u003c\/li\u003e\n\u003cli data-section-id=\"15mtxvd\" data-start=\"3000\" data-end=\"3050\"\u003eIndustrial automation and motion-control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3052\" data-end=\"3055\"\u003e\n\u003ch3 data-section-id=\"1ww87ol\" data-start=\"3057\" data-end=\"3075\"\u003e⭐ Key Benefits\u003c\/h3\u003e\n\u003cul data-start=\"3077\" data-end=\"3329\"\u003e\n\u003cli data-section-id=\"ku0q9w\" data-start=\"3077\" data-end=\"3101\"\u003eImproved power quality\u003c\/li\u003e\n\u003cli data-section-id=\"1vcdiux\" data-start=\"3102\" data-end=\"3142\"\u003eReduced harmonics and electrical noise\u003c\/li\u003e\n\u003cli data-section-id=\"vxnm7t\" data-start=\"3143\" data-end=\"3181\"\u003eEnhanced protection for line modules\u003c\/li\u003e\n\u003cli data-section-id=\"1lshfy5\" data-start=\"3182\" data-end=\"3212\"\u003eIncreased system reliability\u003c\/li\u003e\n\u003cli data-section-id=\"12hc032\" data-start=\"3213\" data-end=\"3236\"\u003eBetter EMC compliance\u003c\/li\u003e\n\u003cli data-section-id=\"177fxm5\" data-start=\"3237\" data-end=\"3280\"\u003eExtended service life of drive components\u003c\/li\u003e\n\u003cli data-section-id=\"6egzsi\" data-start=\"3281\" data-end=\"3329\"\u003eOptimized for SINAMICS S120 Basic Line Modules\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45982548885640,"sku":"6SL3000-0CE24-0AA0","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-06-05T141844.748.jpg?v=1780649334","url":"https:\/\/jjautomation.in\/products\/sinamics-line-reactor-6sl3000-0ce22-0aa0-copy","provider":"JJAutomation","version":"1.0","type":"link"}