{"product_id":"sinamics-s120-active-line-module-6sl3130-7te23-6aa3-copy","title":"SINAMICS S120 Active Line Module 6SL3130-7TE25-5AA3","description":"\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" class=\"\"\u003e\n\u003csection data-turn=\"user\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-141\" data-turn-id-container=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" data-turn-id=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\"\u003e\u003c\/section\u003e\n\u003cp data-start=\"0\" data-end=\"378\"\u003eThe \u003cstrong data-start=\"4\" data-end=\"34\"\u003eSiemens 6SL3130-7TE25-5AA3\u003c\/strong\u003e is a \u003cstrong data-start=\"40\" data-end=\"82\"\u003eSINAMICS S120 Active Line Module (ALM)\u003c\/strong\u003e designed for high-power multi-axis servo and motion control systems. It converts incoming 3-phase AC power into a regulated DC link voltage and enables regenerative braking energy to be fed back into the electrical grid, improving overall system efficiency. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"380\" data-end=\"383\"\u003e\n\u003ch2 data-section-id=\"1wulkwf\" data-start=\"385\" data-end=\"411\"\u003e🔧 Basic Identification\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"413\" data-end=\"836\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"413\" data-end=\"434\"\u003e\n\u003ctr data-start=\"413\" data-end=\"434\"\u003e\n\u003cth data-start=\"413\" data-end=\"423\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"423\" data-end=\"434\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"445\" data-end=\"836\"\u003e\n\u003ctr data-start=\"445\" data-end=\"501\"\u003e\n\u003ctd data-start=\"445\" data-end=\"460\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"460\" data-end=\"501\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003ca class=\"decorated-link\" rel=\"noopener\" href=\"https:\/\/www.siemens.com?utm_source=chatgpt.com\" target=\"_blank\"\u003eSiemens\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"502\" data-end=\"536\"\u003e\n\u003ctd data-start=\"502\" data-end=\"519\" data-col-size=\"sm\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-start=\"519\" data-end=\"536\" data-col-size=\"sm\"\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"537\" data-end=\"573\"\u003e\n\u003ctd data-start=\"537\" data-end=\"551\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"551\" data-end=\"573\"\u003e6SL3130-7TE25-5AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"574\" data-end=\"617\"\u003e\n\u003ctd data-start=\"574\" data-end=\"589\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"589\" data-end=\"617\" data-col-size=\"sm\"\u003eActive Line Module (ALM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"618\" data-end=\"643\"\u003e\n\u003ctd data-start=\"618\" data-end=\"631\" data-col-size=\"sm\"\u003eFrame Size\u003c\/td\u003e\n\u003ctd data-start=\"631\" data-end=\"643\" data-col-size=\"sm\"\u003eBooksize\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"644\" data-end=\"684\"\u003e\n\u003ctd data-start=\"644\" data-end=\"660\" data-col-size=\"sm\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-start=\"660\" data-end=\"684\" data-col-size=\"sm\"\u003e3-phase 380–480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"685\" data-end=\"714\"\u003e\n\u003ctd data-start=\"685\" data-end=\"702\" data-col-size=\"sm\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd data-start=\"702\" data-end=\"714\" data-col-size=\"sm\"\u003e600 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"715\" data-end=\"739\"\u003e\n\u003ctd data-start=\"715\" data-end=\"731\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-start=\"731\" data-end=\"739\" data-col-size=\"sm\"\u003e92 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"740\" data-end=\"763\"\u003e\n\u003ctd data-start=\"740\" data-end=\"754\" data-col-size=\"sm\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"754\" data-end=\"763\"\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"764\" data-end=\"805\"\u003e\n\u003ctd data-start=\"764\" data-end=\"781\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-start=\"781\" data-end=\"805\" data-col-size=\"sm\"\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"806\" data-end=\"836\"\u003e\n\u003ctd data-start=\"806\" data-end=\"822\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"822\" data-end=\"836\" data-col-size=\"sm\"\u003eDRIVE-CLiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"838\" data-end=\"1044\"\u003e📌 Siemens officially describes this module as:\u003cbr data-start=\"885\" data-end=\"888\"\u003e\u003cstrong data-start=\"888\" data-end=\"1006\"\u003e“SINAMICS S120 Active Line Module, input 3AC 380–480V, output DC 600V, 92A, 55kW, Booksize, internal air cooling.”\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1046\" data-end=\"1049\"\u003e\n\u003ch2 data-section-id=\"1kfc8bt\" data-start=\"1051\" data-end=\"1071\"\u003e⚙️ Main Functions\u003c\/h2\u003e\n\u003cp data-start=\"1073\" data-end=\"1111\"\u003eThe 6SL3130-7TE25-5AA3 is designed to:\u003c\/p\u003e\n\u003cul data-start=\"1113\" data-end=\"1440\"\u003e\n\u003cli data-section-id=\"6rrq7t\" data-start=\"1113\" data-end=\"1163\"\u003eConvert 3-phase AC input into a regulated DC bus\u003c\/li\u003e\n\u003cli data-section-id=\"q8kquz\" data-start=\"1164\" data-end=\"1217\"\u003eSupply DC link power to SINAMICS S120 Motor Modules\u003c\/li\u003e\n\u003cli data-section-id=\"93pizs\" data-start=\"1218\" data-end=\"1272\"\u003eReturn regenerative braking energy back to the mains\u003c\/li\u003e\n\u003cli data-section-id=\"4p3pr\" data-start=\"1273\" data-end=\"1331\"\u003eMaintain stable DC link voltage during load fluctuations\u003c\/li\u003e\n\u003cli data-section-id=\"vct2yl\" data-start=\"1332\" data-end=\"1385\"\u003eImprove power factor and reduce harmonic distortion\u003c\/li\u003e\n\u003cli data-section-id=\"x8o5a2\" data-start=\"1386\" data-end=\"1440\"\u003eSupport high-performance synchronized motion systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1442\" data-end=\"1626\"\u003eThe Active Line Module uses an IGBT-based active front end, allowing bidirectional energy flow between the drive system and the electrical supply. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1628\" data-end=\"1631\"\u003e\n\u003ch2 data-section-id=\"1wh6sry\" data-start=\"1633\" data-end=\"1663\"\u003e📋 Technical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1665\" data-end=\"2131\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1665\" data-end=\"1690\"\u003e\n\u003ctr data-start=\"1665\" data-end=\"1690\"\u003e\n\u003cth data-start=\"1665\" data-end=\"1681\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1681\" data-end=\"1690\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1701\" data-end=\"2131\"\u003e\n\u003ctr data-start=\"1701\" data-end=\"1734\"\u003e\n\u003ctd data-start=\"1701\" data-end=\"1716\" data-col-size=\"sm\"\u003eInput Supply\u003c\/td\u003e\n\u003ctd data-start=\"1716\" data-end=\"1734\" data-col-size=\"sm\"\u003e3 AC 380–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1735\" data-end=\"1759\"\u003e\n\u003ctd data-start=\"1735\" data-end=\"1747\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"1747\" data-end=\"1759\" data-col-size=\"sm\"\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1760\" data-end=\"1788\"\u003e\n\u003ctd data-start=\"1760\" data-end=\"1779\" data-col-size=\"sm\"\u003eRated Power (S1)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1779\" data-end=\"1788\"\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1789\" data-end=\"1814\"\u003e\n\u003ctd data-start=\"1789\" data-end=\"1805\" data-col-size=\"sm\"\u003eS6 Duty Power\u003c\/td\u003e\n\u003ctd data-start=\"1805\" data-end=\"1814\" data-col-size=\"sm\"\u003e71 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1815\" data-end=\"1837\"\u003e\n\u003ctd data-start=\"1815\" data-end=\"1828\" data-col-size=\"sm\"\u003ePeak Power\u003c\/td\u003e\n\u003ctd data-start=\"1828\" data-end=\"1837\" data-col-size=\"sm\"\u003e91 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1838\" data-end=\"1872\"\u003e\n\u003ctd data-start=\"1838\" data-end=\"1856\" data-col-size=\"sm\"\u003eDC Link Voltage\u003c\/td\u003e\n\u003ctd data-start=\"1856\" data-end=\"1872\" data-col-size=\"sm\"\u003e510–720 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1873\" data-end=\"1905\"\u003e\n\u003ctd data-start=\"1873\" data-end=\"1897\" data-col-size=\"sm\"\u003eRated DC Link Current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1897\" data-end=\"1905\"\u003e92 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1906\" data-end=\"1938\"\u003e\n\u003ctd data-start=\"1906\" data-end=\"1929\" data-col-size=\"sm\"\u003ePeak DC Link Current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1929\" data-end=\"1938\"\u003e152 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1939\" data-end=\"1977\"\u003e\n\u003ctd data-start=\"1939\" data-end=\"1969\" data-col-size=\"sm\"\u003eRated Input Current (380 V)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1969\" data-end=\"1977\"\u003e88 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1978\" data-end=\"2008\"\u003e\n\u003ctd data-start=\"1978\" data-end=\"1999\" data-col-size=\"sm\"\u003ePeak Input Current\u003c\/td\u003e\n\u003ctd data-start=\"1999\" data-end=\"2008\" data-col-size=\"sm\"\u003e139 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2009\" data-end=\"2041\"\u003e\n\u003ctd data-start=\"2009\" data-end=\"2030\" data-col-size=\"sm\"\u003eElectronics Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2030\" data-end=\"2041\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2042\" data-end=\"2069\"\u003e\n\u003ctd data-start=\"2042\" data-end=\"2061\" data-col-size=\"sm\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2061\" data-end=\"2069\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2070\" data-end=\"2104\"\u003e\n\u003ctd data-start=\"2070\" data-end=\"2080\" data-col-size=\"sm\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2080\" data-end=\"2104\"\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2105\" data-end=\"2131\"\u003e\n\u003ctd data-start=\"2105\" data-end=\"2114\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2114\" data-end=\"2131\" data-col-size=\"sm\"\u003eApprox. 17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"2133\" data-end=\"2261\"\u003eTechnical values are published in Siemens SINAMICS S120 Booksize Power Unit documentation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2263\" data-end=\"2266\"\u003e\n\u003ch2 data-section-id=\"1htuu7e\" data-start=\"2268\" data-end=\"2285\"\u003e🧠 System Role\u003c\/h2\u003e\n\u003cp data-start=\"2287\" data-end=\"2319\"\u003eIn a SINAMICS S120 architecture:\u003c\/p\u003e\n\u003cp data-start=\"2321\" data-end=\"2491\"\u003e\u003cstrong data-start=\"2321\" data-end=\"2342\"\u003eControl Unit (CU)\u003c\/strong\u003e\u003cbr data-start=\"2342\" data-end=\"2345\"\u003e→ controls\u003cbr data-start=\"2355\" data-end=\"2358\"\u003e\u003cstrong data-start=\"2358\" data-end=\"2401\"\u003eActive Line Module (6SL3130-7TE25-5AA3)\u003c\/strong\u003e\u003cbr data-start=\"2401\" data-end=\"2404\"\u003e→ generates regulated DC bus power for\u003cbr data-start=\"2442\" data-end=\"2445\"\u003e\u003cstrong data-start=\"2445\" data-end=\"2462\"\u003eMotor Modules\u003c\/strong\u003e\u003cbr data-start=\"2462\" data-end=\"2465\"\u003e→ drive\u003cbr data-start=\"2472\" data-end=\"2475\"\u003e\u003cstrong data-start=\"2475\" data-end=\"2491\"\u003eservo motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2493\" data-end=\"2661\"\u003eThe Active Line Module acts as the \u003cstrong data-start=\"2528\" data-end=\"2592\"\u003ecentral power infeed and regenerative energy management unit\u003c\/strong\u003e for the complete drive system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2663\" data-end=\"2666\"\u003e\n\u003ch2 data-section-id=\"10eayxy\" data-start=\"2668\" data-end=\"2710\"\u003e🔋 Advantages of Active Line Technology\u003c\/h2\u003e\n\u003cul data-start=\"2712\" data-end=\"2995\"\u003e\n\u003cli data-section-id=\"a35w5y\" data-start=\"2712\" data-end=\"2765\"\u003eRegenerative energy returned to the electrical grid\u003c\/li\u003e\n\u003cli data-section-id=\"rjfrys\" data-start=\"2766\" data-end=\"2826\"\u003eReduced heat generation compared to brake resistor systems\u003c\/li\u003e\n\u003cli data-section-id=\"gbn6fk\" data-start=\"2827\" data-end=\"2852\"\u003eNear-unity power factor\u003c\/li\u003e\n\u003cli data-section-id=\"1ufboww\" data-start=\"2853\" data-end=\"2910\"\u003eStable DC bus voltage independent of mains fluctuations\u003c\/li\u003e\n\u003cli data-section-id=\"1gdt871\" data-start=\"2911\" data-end=\"2938\"\u003eLower harmonic distortion\u003c\/li\u003e\n\u003cli data-section-id=\"1ek5dgi\" data-start=\"2939\" data-end=\"2995\"\u003eHigher energy efficiency in dynamic servo applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2997\" data-end=\"3133\"\u003eThese advantages make Active Line Modules common in advanced CNC and motion-control installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"3135\" data-end=\"3138\"\u003e\n\u003ch2 data-section-id=\"1p2hhyf\" data-start=\"3140\" data-end=\"3166\"\u003e🏭 Typical Applications\u003c\/h2\u003e\n\u003cul data-start=\"3168\" data-end=\"3375\"\u003e\n\u003cli data-section-id=\"1dnkotk\" data-start=\"3168\" data-end=\"3187\"\u003eCNC machine tools\u003c\/li\u003e\n\u003cli data-section-id=\"1n0v9gj\" data-start=\"3188\" data-end=\"3206\"\u003eRobotics systems\u003c\/li\u003e\n\u003cli data-section-id=\"gxxvnd\" data-start=\"3207\" data-end=\"3228\"\u003ePackaging machinery\u003c\/li\u003e\n\u003cli data-section-id=\"xvrxrj\" data-start=\"3229\" data-end=\"3264\"\u003ePrinting and converting equipment\u003c\/li\u003e\n\u003cli data-section-id=\"p8897e\" data-start=\"3265\" data-end=\"3292\"\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli data-section-id=\"190cf5j\" data-start=\"3293\" data-end=\"3327\"\u003eMulti-axis industrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"19o7xap\" data-start=\"3328\" data-end=\"3375\"\u003eSINUMERIK and SIMOTION motion control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3377\" data-end=\"3380\"\u003e\n\u003ch2 data-section-id=\"7dq6ok\" data-start=\"3382\" data-end=\"3417\"\u003e🔍 Comparison Within This Series\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3419\" data-end=\"3588\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3419\" data-end=\"3458\"\u003e\n\u003ctr data-start=\"3419\" data-end=\"3458\"\u003e\n\u003cth data-start=\"3419\" data-end=\"3427\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"3427\" data-end=\"3443\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eRated Current\u003c\/th\u003e\n\u003cth data-start=\"3443\" data-end=\"3458\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eRated Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3475\" data-end=\"3588\"\u003e\n\u003ctr data-start=\"3475\" data-end=\"3512\"\u003e\n\u003ctd data-start=\"3475\" data-end=\"3496\" data-col-size=\"sm\"\u003e6SL3130-7TE21-6AA4\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3496\" data-end=\"3503\"\u003e27 A\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3503\" data-end=\"3512\"\u003e16 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3513\" data-end=\"3550\"\u003e\n\u003ctd data-start=\"3513\" data-end=\"3534\" data-col-size=\"sm\"\u003e6SL3130-7TE23-6AA3\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3534\" data-end=\"3541\"\u003e60 A\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3541\" data-end=\"3550\"\u003e36 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3551\" data-end=\"3588\"\u003e\n\u003ctd data-start=\"3551\" data-end=\"3572\" data-col-size=\"sm\"\u003e6SL3130-7TE25-5AA3\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3572\" data-end=\"3579\"\u003e92 A\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3579\" data-end=\"3588\"\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3590\" data-end=\"3801\"\u003eThe \u003cstrong data-start=\"3594\" data-end=\"3616\"\u003e6SL3130-7TE25-5AA3\u003c\/strong\u003e is the highest-capacity model among these three Active Line Modules and is intended for larger multi-axis drive systems with higher power demands. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"3803\" data-end=\"3806\"\u003e\n\u003ch2 data-section-id=\"rr81fu\" data-start=\"3808\" data-end=\"3839\"\u003e🧾 Short Website Description\u003c\/h2\u003e\n\u003cp data-start=\"3841\" data-end=\"4253\"\u003eThe \u003cstrong data-start=\"3845\" data-end=\"3875\"\u003eSiemens 6SL3130-7TE25-5AA3\u003c\/strong\u003e is a SINAMICS S120 Active Line Module rated at \u003cstrong data-start=\"3923\" data-end=\"3941\"\u003e55 kW and 92 A\u003c\/strong\u003e, designed for high-performance multi-axis servo drive systems. It converts 3-phase AC power into a regulated 600 V DC link while enabling regenerative energy feedback to the mains, making it ideal for CNC machines, robotics, and advanced industrial automation applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45918671175816,"sku":"6SL3130-7TE25-5AA3","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-06-01T131311.357.jpg?v=1780299797","url":"https:\/\/jjautomation.in\/products\/sinamics-s120-active-line-module-6sl3130-7te23-6aa3-copy","provider":"JJAutomation","version":"1.0","type":"link"}