{"product_id":"sinamics-s120-active-line-module-6sl3130-7te31-2aa3-copy","title":"SINAMICS S120 Active Line Module 6SL3162-1AF00-0AA1","description":"\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" class=\"\"\u003e\n\u003csection data-turn=\"user\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-141\" data-turn-id-container=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" data-turn-id=\"bf7d2fd5-1fc9-44c2-a730-cffea4ed0052\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\"\u003e\u003c\/section\u003e\n\u003cp data-start=\"0\" data-end=\"246\"\u003eThe \u003cstrong data-start=\"4\" data-end=\"34\"\u003eSiemens 6SL3162-1AF00-0AA1\u003c\/strong\u003e is a \u003cstrong data-start=\"40\" data-end=\"81\"\u003eSINAMICS S120 Smart Line Module (SLM)\u003c\/strong\u003e used in Siemens industrial drive and motion-control systems. It converts incoming 3-phase AC power into a DC link voltage that supplies SINAMICS S120 Motor Modules.\u003c\/p\u003e\n\u003cp data-start=\"248\" data-end=\"425\"\u003eUnlike Active Line Modules, a Smart Line Module does \u003cstrong data-start=\"301\" data-end=\"353\"\u003enot return regenerative energy to the power grid\u003c\/strong\u003e. Excess braking energy is dissipated through a braking resistor system.\u003c\/p\u003e\n\u003chr data-start=\"427\" data-end=\"430\"\u003e\n\u003ch2 data-section-id=\"1wulkwf\" data-start=\"432\" data-end=\"458\"\u003e🔧 Basic Identification\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"460\" data-end=\"871\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"460\" data-end=\"481\"\u003e\n\u003ctr data-start=\"460\" data-end=\"481\"\u003e\n\u003cth data-start=\"460\" data-end=\"470\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"470\" data-end=\"481\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"492\" data-end=\"871\"\u003e\n\u003ctr data-start=\"492\" data-end=\"548\"\u003e\n\u003ctd data-start=\"492\" data-end=\"507\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"507\" data-end=\"548\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003ca class=\"decorated-link\" rel=\"noopener\" href=\"https:\/\/www.siemens.com?utm_source=chatgpt.com\" target=\"_blank\"\u003eSiemens\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"549\" data-end=\"583\"\u003e\n\u003ctd data-start=\"549\" data-end=\"566\" data-col-size=\"sm\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-start=\"566\" data-end=\"583\" data-col-size=\"sm\"\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"584\" data-end=\"620\"\u003e\n\u003ctd data-start=\"584\" data-end=\"598\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"598\" data-end=\"620\"\u003e6SL3162-1AF00-0AA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"621\" data-end=\"663\"\u003e\n\u003ctd data-start=\"621\" data-end=\"636\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"636\" data-end=\"663\" data-col-size=\"sm\"\u003eSmart Line Module (SLM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"664\" data-end=\"708\"\u003e\n\u003ctd data-start=\"664\" data-end=\"678\" data-col-size=\"sm\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"678\" data-end=\"708\"\u003eSINAMICS S120 Drive System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"709\" data-end=\"749\"\u003e\n\u003ctd data-start=\"709\" data-end=\"725\" data-col-size=\"sm\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"725\" data-end=\"749\"\u003e3-phase 380–480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"750\" data-end=\"785\"\u003e\n\u003ctd data-start=\"750\" data-end=\"767\" data-col-size=\"sm\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"767\" data-end=\"785\"\u003eDC Link Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"786\" data-end=\"829\"\u003e\n\u003ctd data-start=\"786\" data-end=\"803\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-start=\"803\" data-end=\"829\" data-col-size=\"sm\"\u003eIntegrated air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"830\" data-end=\"871\"\u003e\n\u003ctd data-start=\"830\" data-end=\"846\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"846\" data-end=\"871\"\u003eDRIVE-CLiQ compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"873\" data-end=\"1033\"\u003e📌 Siemens classifies this unit as a \u003cstrong data-start=\"910\" data-end=\"945\"\u003eSINAMICS S120 Smart Line Module\u003c\/strong\u003e, designed as a compact and cost-effective power infeed solution for S120 drive systems.\u003c\/p\u003e\n\u003chr data-start=\"1035\" data-end=\"1038\"\u003e\n\u003ch2 data-section-id=\"1kfc8bt\" data-start=\"1040\" data-end=\"1060\"\u003e⚙️ Main Functions\u003c\/h2\u003e\n\u003cp data-start=\"1062\" data-end=\"1100\"\u003eThe 6SL3162-1AF00-0AA1 is designed to:\u003c\/p\u003e\n\u003cul data-start=\"1102\" data-end=\"1402\"\u003e\n\u003cli data-section-id=\"1kx2b5y\" data-start=\"1102\" data-end=\"1150\"\u003eConvert 3-phase AC supply into DC link voltage\u003c\/li\u003e\n\u003cli data-section-id=\"57o8s\" data-start=\"1151\" data-end=\"1196\"\u003eSupply power to SINAMICS S120 Motor Modules\u003c\/li\u003e\n\u003cli data-section-id=\"1xd9obi\" data-start=\"1197\" data-end=\"1238\"\u003eProvide a compact power infeed solution\u003c\/li\u003e\n\u003cli data-section-id=\"12ym0x1\" data-start=\"1239\" data-end=\"1299\"\u003eSupport braking resistor operation for regenerative energy\u003c\/li\u003e\n\u003cli data-section-id=\"p1j8hh\" data-start=\"1300\" data-end=\"1348\"\u003eReduce system complexity and installation cost\u003c\/li\u003e\n\u003cli data-section-id=\"vunfid\" data-start=\"1349\" data-end=\"1402\"\u003eOperate within multi-axis servo drive architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1404\" data-end=\"1407\"\u003e\n\u003ch2 data-section-id=\"1wh6sry\" data-start=\"1409\" data-end=\"1439\"\u003e📋 Technical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1441\" data-end=\"1733\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1441\" data-end=\"1466\"\u003e\n\u003ctr data-start=\"1441\" data-end=\"1466\"\u003e\n\u003cth data-start=\"1441\" data-end=\"1457\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1457\" data-end=\"1466\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1477\" data-end=\"1733\"\u003e\n\u003ctr data-start=\"1477\" data-end=\"1510\"\u003e\n\u003ctd data-start=\"1477\" data-end=\"1492\" data-col-size=\"sm\"\u003eInput Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1492\" data-end=\"1510\"\u003e3 AC 380–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1511\" data-end=\"1535\"\u003e\n\u003ctd data-start=\"1511\" data-end=\"1523\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"1523\" data-end=\"1535\" data-col-size=\"sm\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1536\" data-end=\"1561\"\u003e\n\u003ctd data-start=\"1536\" data-end=\"1550\" data-col-size=\"sm\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1550\" data-end=\"1561\"\u003eDC Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1562\" data-end=\"1602\"\u003e\n\u003ctd data-start=\"1562\" data-end=\"1585\" data-col-size=\"sm\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1585\" data-end=\"1602\"\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1603\" data-end=\"1634\"\u003e\n\u003ctd data-start=\"1603\" data-end=\"1620\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-start=\"1620\" data-end=\"1634\" data-col-size=\"sm\"\u003eAir cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1635\" data-end=\"1662\"\u003e\n\u003ctd data-start=\"1635\" data-end=\"1654\" data-col-size=\"sm\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1654\" data-end=\"1662\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1663\" data-end=\"1692\"\u003e\n\u003ctd data-start=\"1663\" data-end=\"1680\" data-col-size=\"sm\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1680\" data-end=\"1692\"\u003eBooksize\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1693\" data-end=\"1733\"\u003e\n\u003ctd data-start=\"1693\" data-end=\"1719\" data-col-size=\"sm\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1719\" data-end=\"1733\"\u003eDRIVE-CLiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1735\" data-end=\"1738\"\u003e\n\u003ch2 data-section-id=\"1htuu7e\" data-start=\"1740\" data-end=\"1757\"\u003e🧠 System Role\u003c\/h2\u003e\n\u003cp data-start=\"1759\" data-end=\"1791\"\u003eIn a SINAMICS S120 architecture:\u003c\/p\u003e\n\u003cp data-start=\"1793\" data-end=\"1950\"\u003e\u003cstrong data-start=\"1793\" data-end=\"1814\"\u003eControl Unit (CU)\u003c\/strong\u003e\u003cbr data-start=\"1814\" data-end=\"1817\"\u003e→ controls\u003cbr data-start=\"1827\" data-end=\"1830\"\u003e\u003cstrong data-start=\"1830\" data-end=\"1872\"\u003eSmart Line Module (6SL3162-1AF00-0AA1)\u003c\/strong\u003e\u003cbr data-start=\"1872\" data-end=\"1875\"\u003e→ supplies DC bus power to\u003cbr data-start=\"1901\" data-end=\"1904\"\u003e\u003cstrong data-start=\"1904\" data-end=\"1921\"\u003eMotor Modules\u003c\/strong\u003e\u003cbr data-start=\"1921\" data-end=\"1924\"\u003e→ drive\u003cbr data-start=\"1931\" data-end=\"1934\"\u003e\u003cstrong data-start=\"1934\" data-end=\"1950\"\u003eservo motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1952\" data-end=\"2043\"\u003eThe Smart Line Module acts as the \u003cstrong data-start=\"1986\" data-end=\"2021\"\u003emain AC-to-DC power supply unit\u003c\/strong\u003e for the drive system.\u003c\/p\u003e\n\u003chr data-start=\"2045\" data-end=\"2048\"\u003e\n\u003ch2 data-section-id=\"1jo2hab\" data-start=\"2050\" data-end=\"2095\"\u003e🔋 Smart Line Module vs Active Line Module\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2097\" data-end=\"2405\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2097\" data-end=\"2149\"\u003e\n\u003ctr data-start=\"2097\" data-end=\"2149\"\u003e\n\u003cth data-start=\"2097\" data-end=\"2107\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2107\" data-end=\"2127\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSmart Line Module\u003c\/th\u003e\n\u003cth data-start=\"2127\" data-end=\"2149\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eActive Line Module\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2164\" data-end=\"2405\"\u003e\n\u003ctr data-start=\"2164\" data-end=\"2199\"\u003e\n\u003ctd data-start=\"2164\" data-end=\"2186\" data-col-size=\"sm\"\u003eAC to DC Conversion\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2186\" data-end=\"2192\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2192\" data-end=\"2199\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2200\" data-end=\"2244\"\u003e\n\u003ctd data-start=\"2200\" data-end=\"2232\" data-col-size=\"sm\"\u003eRegenerative Feedback to Grid\u003c\/td\u003e\n\u003ctd data-start=\"2232\" data-end=\"2237\" data-col-size=\"sm\"\u003eNo\u003c\/td\u003e\n\u003ctd data-start=\"2237\" data-end=\"2244\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2245\" data-end=\"2293\"\u003e\n\u003ctd data-start=\"2245\" data-end=\"2273\" data-col-size=\"sm\"\u003eBraking Resistor Required\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2273\" data-end=\"2279\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2279\" data-end=\"2293\"\u003eUsually No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2294\" data-end=\"2338\"\u003e\n\u003ctd data-start=\"2294\" data-end=\"2315\" data-col-size=\"sm\"\u003eHarmonic Reduction\u003c\/td\u003e\n\u003ctd data-start=\"2315\" data-end=\"2326\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2326\" data-end=\"2338\"\u003eAdvanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2339\" data-end=\"2364\"\u003e\n\u003ctd data-start=\"2339\" data-end=\"2346\" data-col-size=\"sm\"\u003eCost\u003c\/td\u003e\n\u003ctd data-start=\"2346\" data-end=\"2354\" data-col-size=\"sm\"\u003eLower\u003c\/td\u003e\n\u003ctd data-start=\"2354\" data-end=\"2364\" data-col-size=\"sm\"\u003eHigher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2365\" data-end=\"2405\"\u003e\n\u003ctd data-start=\"2365\" data-end=\"2385\" data-col-size=\"sm\"\u003eEnergy Efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2385\" data-end=\"2392\"\u003eGood\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2392\" data-end=\"2405\"\u003eExcellent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"2407\" data-end=\"2546\"\u003eSmart Line Modules are commonly selected where regenerative energy recovery is not required and a simpler system architecture is preferred.\u003c\/p\u003e\n\u003chr data-start=\"2548\" data-end=\"2551\"\u003e\n\u003ch2 data-section-id=\"1p2hhyf\" data-start=\"2553\" data-end=\"2579\"\u003e🏭 Typical Applications\u003c\/h2\u003e\n\u003cul data-start=\"2581\" data-end=\"2756\"\u003e\n\u003cli data-section-id=\"1dnkotk\" data-start=\"2581\" data-end=\"2600\"\u003eCNC machine tools\u003c\/li\u003e\n\u003cli data-section-id=\"gxxvnd\" data-start=\"2601\" data-end=\"2622\"\u003ePackaging machinery\u003c\/li\u003e\n\u003cli data-section-id=\"ks4s2z\" data-start=\"2623\" data-end=\"2641\"\u003eConveyor systems\u003c\/li\u003e\n\u003cli data-section-id=\"8usc4m\" data-start=\"2642\" data-end=\"2671\"\u003eMaterial handling equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1lil36f\" data-start=\"2672\" data-end=\"2692\"\u003ePrinting machinery\u003c\/li\u003e\n\u003cli data-section-id=\"jeijeu\" data-start=\"2693\" data-end=\"2724\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli data-section-id=\"1fii8d7\" data-start=\"2725\" data-end=\"2756\"\u003eMulti-axis servo applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2758\" data-end=\"2761\"\u003e\n\u003ch2 data-section-id=\"g1di11\" data-start=\"2763\" data-end=\"2781\"\u003e🔍 Key Features\u003c\/h2\u003e\n\u003cul data-start=\"2783\" data-end=\"3016\"\u003e\n\u003cli data-section-id=\"i64xfx\" data-start=\"2783\" data-end=\"2828\"\u003eCompact SINAMICS S120 power infeed solution\u003c\/li\u003e\n\u003cli data-section-id=\"gscoho\" data-start=\"2829\" data-end=\"2880\"\u003eCost-effective alternative to Active Line Modules\u003c\/li\u003e\n\u003cli data-section-id=\"19w6b1l\" data-start=\"2881\" data-end=\"2916\"\u003eSupports multi-axis drive systems\u003c\/li\u003e\n\u003cli data-section-id=\"cs8334\" data-start=\"2917\" data-end=\"2941\"\u003eDRIVE-CLiQ integration\u003c\/li\u003e\n\u003cli data-section-id=\"18xay5x\" data-start=\"2942\" data-end=\"2970\"\u003eReliable DC bus generation\u003c\/li\u003e\n\u003cli data-section-id=\"b1nxse\" data-start=\"2971\" data-end=\"3016\"\u003eEasy integration with SINAMICS architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3018\" data-end=\"3021\"\u003e\n\u003ch2 data-section-id=\"rr81fu\" data-start=\"3023\" data-end=\"3054\"\u003e🧾 Short Website Description\u003c\/h2\u003e\n\u003cp data-start=\"3056\" data-end=\"3429\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"3060\" data-end=\"3090\"\u003eSiemens 6SL3162-1AF00-0AA1\u003c\/strong\u003e is a SINAMICS S120 Smart Line Module designed to provide reliable AC-to-DC power conversion for industrial servo drive systems. Used as the main power infeed unit for SINAMICS S120 architectures, it delivers stable DC link voltage for motor modules and is ideal for CNC machines, packaging systems, and industrial automation applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45918853628040,"sku":"6SL3162-1AF00-0AA1","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-06-01T154847.669.jpg?v=1780309134","url":"https:\/\/jjautomation.in\/products\/sinamics-s120-active-line-module-6sl3130-7te31-2aa3-copy","provider":"JJAutomation","version":"1.0","type":"link"}