{"product_id":"sinamics-terminal-kit-6sl3163-8ld00-0aa0-copy","title":"SINAMICS Line Reactor 6SL3000-0CE22-0AA0","description":"\u003ch3 data-end=\"42\" data-start=\"0\" data-section-id=\"89djpy\"\u003eSiemens 6SL3000-0CE22-0AA0 Description\u003c\/h3\u003e\n\u003cp data-end=\"604\" data-start=\"44\"\u003eThe \u003cstrong data-end=\"78\" data-start=\"48\"\u003eSiemens 6SL3000-0CE22-0AA0\u003c\/strong\u003e is a \u003cstrong data-end=\"114\" data-start=\"84\"\u003eSINAMICS S120 Line Reactor\u003c\/strong\u003e designed for use with \u003cstrong data-end=\"171\" data-start=\"137\"\u003e20 kW Basic Line Modules (BLM)\u003c\/strong\u003e. Operating on \u003cstrong data-end=\"220\" data-start=\"186\"\u003e3-phase 380–480 V AC, 50\/60 Hz\u003c\/strong\u003e, the line reactor is installed between the mains supply and the Basic Line Module to reduce harmonic distortion, limit inrush currents, improve electromagnetic compatibility (EMC), and protect drive components from line-side disturbances. It is an essential component for ensuring reliable and efficient operation of SINAMICS S120 drive systems. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"944\" data-start=\"606\"\u003eAs part of the SINAMICS S120 power infrastructure, the reactor provides the line impedance required for proper Basic Line Module operation. By reducing current peaks and harmonics, it helps protect rectifier components, extends equipment life, and improves overall system stability and power quality. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1206\" data-start=\"946\"\u003eThe 6SL3000-0CE22-0AA0 is commonly used in CNC machine tools, packaging machinery, robotics, material handling systems, printing equipment, and industrial automation applications utilizing SINAMICS S120 Basic Line Modules. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"1211\" data-start=\"1208\"\u003e\n\u003ch3 data-end=\"1240\" data-start=\"1213\" data-section-id=\"hc1qto\"\u003e🔧 Basic Identification\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"1609\" data-start=\"1242\"\u003e\n\u003cthead data-end=\"1263\" data-start=\"1242\"\u003e\n\u003ctr data-end=\"1263\" data-start=\"1242\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"1252\" data-start=\"1242\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"1263\" data-start=\"1252\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"1609\" data-start=\"1288\"\u003e\n\u003ctr data-end=\"1314\" data-start=\"1288\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1303\" data-start=\"1288\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-end=\"1314\" data-start=\"1303\" data-col-size=\"sm\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1349\" data-start=\"1315\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1332\" data-start=\"1315\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1349\" data-start=\"1332\"\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1386\" data-start=\"1350\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1364\" data-start=\"1350\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-end=\"1386\" data-start=\"1364\" data-col-size=\"sm\"\u003e6SL3000-0CE22-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1418\" data-start=\"1387\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1402\" data-start=\"1387\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1418\" data-start=\"1402\"\u003eLine Reactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1460\" data-start=\"1419\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1433\" data-start=\"1419\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1460\" data-start=\"1433\"\u003eBasic Line Module (BLM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1496\" data-start=\"1461\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1487\" data-start=\"1461\"\u003eCompatible Power Rating\u003c\/td\u003e\n\u003ctd data-end=\"1496\" data-start=\"1487\" data-col-size=\"sm\"\u003e20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1531\" data-start=\"1497\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1513\" data-start=\"1497\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1531\" data-start=\"1513\"\u003e3 AC 380–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1556\" data-start=\"1532\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1544\" data-start=\"1532\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-end=\"1556\" data-start=\"1544\" data-col-size=\"sm\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1581\" data-start=\"1557\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1573\" data-start=\"1557\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1581\" data-start=\"1573\"\u003e34 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1609\" data-start=\"1582\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1601\" data-start=\"1582\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-end=\"1609\" data-start=\"1601\" data-col-size=\"sm\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"1648\" data-start=\"1611\"\u003e \u003c\/p\u003e\n\u003chr data-end=\"1653\" data-start=\"1650\"\u003e\n\u003ch3 data-end=\"1676\" data-start=\"1655\" data-section-id=\"hfo6i2\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-end=\"2010\" data-start=\"1678\"\u003e\n\u003cli data-end=\"1727\" data-start=\"1678\" data-section-id=\"1cedhz2\"\u003eReduces harmonic distortion on the mains supply\u003c\/li\u003e\n\u003cli data-end=\"1764\" data-start=\"1728\" data-section-id=\"zrz0yp\"\u003eLimits startup and inrush currents\u003c\/li\u003e\n\u003cli data-end=\"1811\" data-start=\"1765\" data-section-id=\"1nu4bq5\"\u003eImproves electromagnetic compatibility (EMC)\u003c\/li\u003e\n\u003cli data-end=\"1865\" data-start=\"1812\" data-section-id=\"12yi0o6\"\u003eProtects Basic Line Modules from voltage transients\u003c\/li\u003e\n\u003cli data-end=\"1913\" data-start=\"1866\" data-section-id=\"1ap63lp\"\u003eEnhances power quality and system reliability\u003c\/li\u003e\n\u003cli data-end=\"1962\" data-start=\"1914\" data-section-id=\"1ihrbhm\"\u003eReduces electrical stress on power electronics\u003c\/li\u003e\n\u003cli data-end=\"2010\" data-start=\"1963\" data-section-id=\"g86sox\"\u003eSupports stable SINAMICS S120 drive operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2049\" data-start=\"2012\"\u003e \u003c\/p\u003e\n\u003chr data-end=\"2054\" data-start=\"2051\"\u003e\n\u003ch3 data-end=\"2087\" data-start=\"2056\" data-section-id=\"12k99m5\"\u003e📋 Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2424\" data-start=\"2089\"\u003e\n\u003cthead data-end=\"2114\" data-start=\"2089\"\u003e\n\u003ctr data-end=\"2114\" data-start=\"2089\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"2105\" data-start=\"2089\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"2114\" data-start=\"2105\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2424\" data-start=\"2125\"\u003e\n\u003ctr data-end=\"2156\" data-start=\"2125\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2140\" data-start=\"2125\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2156\" data-start=\"2140\"\u003eLine Reactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2204\" data-start=\"2157\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2177\" data-start=\"2157\"\u003eCompatible Module\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2204\" data-start=\"2177\"\u003e20 kW Basic Line Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2240\" data-start=\"2205\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2222\" data-start=\"2205\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-end=\"2240\" data-start=\"2222\" data-col-size=\"sm\"\u003e3 AC 380–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2271\" data-start=\"2241\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2259\" data-start=\"2241\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd data-end=\"2271\" data-start=\"2259\" data-col-size=\"sm\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2296\" data-start=\"2272\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2288\" data-start=\"2272\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-end=\"2296\" data-start=\"2288\" data-col-size=\"sm\"\u003e34 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2329\" data-start=\"2297\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2310\" data-start=\"2297\"\u003eInductance\u003c\/td\u003e\n\u003ctd data-end=\"2329\" data-start=\"2310\" data-col-size=\"sm\"\u003eApprox. 0.46 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2358\" data-start=\"2330\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2350\" data-start=\"2330\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-end=\"2358\" data-start=\"2350\" data-col-size=\"sm\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2386\" data-start=\"2359\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2368\" data-start=\"2359\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-end=\"2386\" data-start=\"2368\" data-col-size=\"sm\"\u003eApprox. 5.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2424\" data-start=\"2387\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2405\" data-start=\"2387\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd data-end=\"2424\" data-start=\"2405\" data-col-size=\"sm\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"2463\" data-start=\"2426\"\u003e \u003c\/p\u003e\n\u003chr data-end=\"2468\" data-start=\"2465\"\u003e\n\u003ch3 data-end=\"2488\" data-start=\"2470\" data-section-id=\"zb3ky1\"\u003e🧠 System Role\u003c\/h3\u003e\n\u003cp data-end=\"2522\" data-start=\"2490\"\u003eIn a SINAMICS S120 architecture:\u003c\/p\u003e\n\u003cp data-end=\"2698\" data-start=\"2524\"\u003e\u003cstrong data-end=\"2544\" data-start=\"2524\"\u003e3-Phase AC Mains\u003c\/strong\u003e\u003cbr data-end=\"2547\" data-start=\"2544\"\u003e→ \u003cstrong data-end=\"2584\" data-start=\"2549\"\u003e6SL3000-0CE22-0AA0 Line Reactor\u003c\/strong\u003e\u003cbr data-end=\"2587\" data-start=\"2584\"\u003e→ \u003cstrong data-end=\"2616\" data-start=\"2589\"\u003e20 kW Basic Line Module\u003c\/strong\u003e\u003cbr data-end=\"2619\" data-start=\"2616\"\u003e→ \u003cstrong data-end=\"2638\" data-start=\"2621\"\u003e600 V DC Link\u003c\/strong\u003e\u003cbr data-end=\"2641\" data-start=\"2638\"\u003e→ \u003cstrong data-end=\"2660\" data-start=\"2643\"\u003eMotor Modules\u003c\/strong\u003e\u003cbr data-end=\"2663\" data-start=\"2660\"\u003e→ \u003cstrong data-end=\"2698\" data-start=\"2665\"\u003eServo Motors \/ Spindle Motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"2921\" data-start=\"2700\"\u003eThe line reactor conditions incoming power and provides the required line-side impedance for reliable Basic Line Module operation while reducing harmonics and electrical disturbances. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"2926\" data-start=\"2923\"\u003e\n\u003ch3 data-end=\"2955\" data-start=\"2928\" data-section-id=\"1tre2jo\"\u003e🏭 Typical Applications\u003c\/h3\u003e\n\u003cul data-end=\"3193\" data-start=\"2957\"\u003e\n\u003cli data-end=\"2980\" data-start=\"2957\" data-section-id=\"6siw3i\"\u003eCNC machining centers\u003c\/li\u003e\n\u003cli data-end=\"3017\" data-start=\"2981\" data-section-id=\"13thph4\"\u003eSINUMERIK-controlled machine tools\u003c\/li\u003e\n\u003cli data-end=\"3039\" data-start=\"3018\" data-section-id=\"gxxvnd\"\u003ePackaging machinery\u003c\/li\u003e\n\u003cli data-end=\"3058\" data-start=\"3040\" data-section-id=\"1n0v9gj\"\u003eRobotics systems\u003c\/li\u003e\n\u003cli data-end=\"3088\" data-start=\"3059\" data-section-id=\"8usc4m\"\u003eMaterial handling equipment\u003c\/li\u003e\n\u003cli data-end=\"3123\" data-start=\"3089\" data-section-id=\"7q2k7n\"\u003ePrinting and converting machines\u003c\/li\u003e\n\u003cli data-end=\"3142\" data-start=\"3124\" data-section-id=\"ks4s2z\"\u003eConveyor systems\u003c\/li\u003e\n\u003cli data-end=\"3193\" data-start=\"3143\" data-section-id=\"15mtxvd\"\u003eIndustrial automation and motion-control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3198\" data-start=\"3195\"\u003e\n\u003ch3 data-end=\"3218\" data-start=\"3200\" data-section-id=\"1ww87ol\"\u003e⭐ Key Benefits\u003c\/h3\u003e\n\u003cul data-end=\"3472\" data-start=\"3220\"\u003e\n\u003cli data-end=\"3244\" data-start=\"3220\" data-section-id=\"ku0q9w\"\u003eImproved power quality\u003c\/li\u003e\n\u003cli data-end=\"3285\" data-start=\"3245\" data-section-id=\"1vcdiux\"\u003eReduced harmonics and electrical noise\u003c\/li\u003e\n\u003cli data-end=\"3324\" data-start=\"3286\" data-section-id=\"vxnm7t\"\u003eEnhanced protection for line modules\u003c\/li\u003e\n\u003cli data-end=\"3355\" data-start=\"3325\" data-section-id=\"1lshfy5\"\u003eIncreased system reliability\u003c\/li\u003e\n\u003cli data-end=\"3379\" data-start=\"3356\" data-section-id=\"12hc032\"\u003eBetter EMC compliance\u003c\/li\u003e\n\u003cli data-end=\"3423\" data-start=\"3380\" data-section-id=\"177fxm5\"\u003eExtended service life of drive components\u003c\/li\u003e\n\u003cli data-end=\"3472\" data-start=\"3424\" data-section-id=\"6egzsi\"\u003eOptimized for SINAMICS S120 Basic Line Modules\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JJAutomation","offers":[{"title":"Default Title","offer_id":45982248108168,"sku":"6SL3000-0CE22-0AA0","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/1903\/3224\/files\/WhatsAppImage2025-10-18at1.47.49PM-2026-06-05T141844.748.jpg?v=1780649334","url":"https:\/\/jjautomation.in\/products\/sinamics-terminal-kit-6sl3163-8ld00-0aa0-copy","provider":"JJAutomation","version":"1.0","type":"link"}