Mitsubishi MDS alarm 19 means an encoder communication error in synchronous control — an error was detected in the MACHINE-side encoder of the SECONDARY axis during speed-command synchronization. This is a servo-side alarm on synchronous-axis configurations (twin-drive gantries and tables where two motors run one axis): the secondary axis's scale/encoder feedback chain — often running through an MDS-B-HR interface unit — dropped out.

Mitsubishi's six steps, in prose

  1. Check the secondary axis's encoder parameter — SV025 (pen, position encoder): the machine-side encoder type must be declared correctly for the secondary axis specifically — a restore or setup that got the primary right and the secondary wrong produces exactly this alarm.
  2. Check the linear scale → MDS-B-HR connection — including Mitsubishi's wonderfully specific check: is the screw connecting to the MDS-B-HR wound down? A backed-off terminal screw at the interface unit is a documented, real-world cause — tighten it. Inspect the whole scale-to-HR connection while there.
  3. Jiggle-test the encoder connectors (drive end and encoder end) — loose → install correctly.
  4. Power OFF and meter the encoder cable — faulty → replace.
  5. Swap-test to split drive vs encoder side — the alarm follows the guilty unit.
  6. Ambient environment — machine grounding and cable shielding: gantry axes have long cable runs through moving carriers, making them the most noise- and flex-exposed feedback chains on the machine.
Tip: On a synchronous pair, always ask which axis the alarm names — the SECONDARY's machine-side chain is the suspect, even though the symptom (gantry down) feels global. And take alarm 19 seriously on gantries: a secondary axis running on corrupted feedback in synchronization is how gantries rack and bind. The drag-chain section of the secondary's scale cable is the single most common physical find — flex it while metering.

Diagnosis checklist (in order)

  1. Verify SV025.pen on the SECONDARY axis.
  2. Inspect the scale→MDS-B-HR connection; tighten the terminal screws.
  3. Reseat/jiggle connectors; meter the cable with flexing (drag-chain section especially).
  4. Swap-test drive vs encoder side; repair/replace accordingly.
  5. Intermittents → grounding and shielding of the long secondary-axis runs.