Fanuc spindle alarm 79 occurs only with Dual Check Safety, and means an abnormal operation was detected during the initial test — the self-verification sequence the safety function runs at start-up did not behave as expected. It is the catch-all of the DCS power-up family: where AL-74 names the CPU test and AL-75 the CRC test, AL-79 reports the initial test sequence itself going wrong.

Fanuc's remedy — with the standard preamble

The manual: replace the Spindle Amplifier or its control printed-circuit board. Before that, the same ten-minute preamble as its siblings — which regularly saves a board from an unnecessary trip:

  1. One clean power cycle: full off, charge LEDs out, on. A power dip mid-test aborts the sequence spuriously (see AL-10 for control-supply health). Once — a repeat is real.
  2. Reseat the control-board faceplate (power off, locked out) — a half-seated board-to-board connection disturbs the test environment; the standing first fix of this series.
  3. History check: AL-79 arriving alongside AL-74/75/76 confirms a failing board environment — one repair covers the family. AL-79 immediately after board/software work → verify board pedigree and software series/edition first.

The repair

A persistent AL-79 is a control-board fault in the safety test path — board-level repair (processor environment, storage, supply rails) or an exact-specification exchange. Acceptance, as for every safety-chain repair: a documented safety-function test, demonstrating the initial test completes and the safety monitoring intervenes correctly — not merely a clean boot.

Tip: The DCS power-up codes (74, 75, 76, 79) share causes, share fixes, and usually share a single failing board. Diagnose them as one case, not four — and if they cluster on cold mornings or after mains events, the board's ageing electronics (or your incoming power quality) is the real patient.

Related guides

AL-79 at power-up? JJ Automation repairs Dual Check Safety control boards at component level with documented safety-function acceptance testing. Exact-spec exchange amplifiers in stock, on-site diagnosis in NCR. WhatsApp us or call +91 88022 12394.